4 改訂履歴
Changes from B Revision (March 2018) to C Revision
- Added 概略回路図に、オプションの破線のボックスをGo
- Added TableNote to Table 2Go
- Added dashed box with optional on it in Figure 30Go
- Added PSE and POE information to Opto-isolators for TPH, TPL and BTGo
Changes from A Revision (October 2017) to B Revision
- Changed TPS2373-3の標準電流制限を1.85AにGo
- Deleted the VAPD typical value Go
- Changed minimum, typical, and maximum values of VAPD rising thresholdGo
- Added minimum and maximum values of VAPDH in the Electrical Characteristics tableGo
- Changed current limit nominal value to 1.85 and maximum value to 2.2Go
- Changed minimum value of inrush termination to 65%Go
- Changed typical shutdown temperature to 158°CGo
- Added TPS2373-4 to the title of Figure 11Go
- Changed Functional Block Diagram imageGo
- Changed "current limit is changed to 1.8 A" to "current limit is changed to 1.85 A" in Internal Pass MOSFET subsectionGo
- Added "The VC switch ..." sentence to VC_IN, VC_OUT, UVLO_SEL, and Advanced PWM Setup subsectionGo
- Changed "~" to "approximately" and "1.8 A" to "1.85 A" in the Advanced Startup and Converter Operation subsectionGo
- Added reference for guidance on how to handle PoE shutdown conditions to the Advanced Startup and Converter Operation subsectionGo
- Changed Typical Application CircuitGo
- Changed "KΩ" to "kΩ" and "1.65 V" to "1.75 V" in Equation 2Go
- Changed "232 kΩ" to "221 kΩ" in Equation 3Go
- Added sentence to end of the APD Pin Divider Network RAPD1, RAPD2 subsectionGo
- Added information to end of the VC Input and Output, CVCIN and CVCOUT subsectionGo
- Changed equation 7 values in Automatic MPS and MPS Duty Cycle, RMPS and RMPS_DUTYGo
- Changed TPS2373-3をアクティブにGo
Changes from * Revision (June 2017) to A Revision
- Changed Automatic MPS falling current threshold MIN from 21.5 to 18, MAX from 34.5 to 38 Go