SBOA575 September 2023 INA823 , OPA2387 , XTR115 , XTR116
A high accuracy bridge amplifier to 4-20-mA current loop transmitter was successfully designed and measured. The final results are summarized in Table 6-1.
Design Criteria | Results & Comments |
---|---|
Use XTR references (4.096-V and 5-V) to power sensor and amplifier circuitry | Design only uses XTR reference voltages |
Total current consumption < 3.5-mA | Total current consumption = 3.39mA |
Weight range = 0 to 20-lbs → output current = 4 to 20-mA | Weight range = 0 to 20-lbs → output current = 4.0994 to 20.1545-mA. Approximately 0.1-mA offset due to limits of standard resistor values. |
±0.1% accuracy | Design is accurate to ±0.1% |