SNLA246C October   2015  – April 2024 DP83867CR , DP83867CS , DP83867E , DP83867IR , DP83867IS

 

  1.   1
  2.   Trademarks
  3. 1Introduction
  4. 2Troubleshooting the Application
    1. 2.1 Read and Check Register Values for Basic Health Check
    2. 2.2 Schematic and Layout Checklist
    3. 2.3 Component Checklist
      1. 2.3.1 Magnetics
      2. 2.3.2 Crystal / Oscillator
    4. 2.4 Peripheral Pin Checks
      1. 2.4.1 Power Supplies
      2. 2.4.2 RBIAS Voltage and Resistance
      3. 2.4.3 Probe the XI Clock
      4. 2.4.4 Probe the RESET_N Signal
      5. 2.4.5 Probe the Strap Pins During Initialization
      6. 2.4.6 Probe the Serial Management Interface Signals (MDC, MDIO)
      7. 2.4.7 Probe the MDI Signals
    5. 2.5 Link Quality Check
    6. 2.6 Built-in Self Test With Various Loopback Modes
    7. 2.7 Debugging MAC Interface
      1. 2.7.1 RGMII Debug
      2. 2.7.2 SGMII Debug
  5. 3Application Specific Debugs
    1. 3.1 Improving Link-up Margins for Short Cables
    2. 3.2 Improving Link Margins across Different Channels
    3. 3.3 Link up in 100Mbps Full Duplex Force Mode
    4. 3.4 Unstable Link Up Debug in 1Gbps communication
    5. 3.5 DP83867PHY and DP83867PHY Cannot Link Up in 1Gbps
    6. 3.6 Compliance Debug
    7. 3.7 EMC Debug
    8. 3.8 Tools and References
      1. 3.8.1 DP83867 Register Access
      2. 3.8.2 Extended Register Access
  6. 4Conclusion
  7. 5References
  8. 6Revision History

EMC Debug

The following section mainly go over the general guideline on how to debug EMC issue on DP83867PHY.
  • Check the test setup:

    EMC test:

    • No loop cable
      GUID-20240307-SS0I-RNKR-X5BS-1WQ8KS1C7R1H-low.svg
    • Place the cable away from the emission source or Antenna (mainly on RE test)
    • Shielded cable is preferred
    • Make sure the test board and test equipment match (mainly on CE test)
      • Cable type needs to match the CDN test equipment
    • Turn off CLK_OUT when it is open or not used
    • EMI test:
      • Check the ground path of both test board and test equipment
      • Shielded cable is preferred
      • Make sure the cable type match with test equipment (mainly on CI test)
        • Cable type needs to match the CDN test equipment
  • Check the schematic
    • Make sure there is a ground isolation

      Make sure there is a ground isolation path (R//C) between connector ground and earth ground

      Make sure the Transformer follow data sheet specification

      No shorted center taps on transformer

      Double check on the capacitors on the center taps of transformer

      Remove ESD diodes on MDI lines for compliance test

      Check Rbias value and make sure the value falls in the 1% range

      Follow the schematic check list recommendation in Section 2.2

  • Check the layout
    • Make sure no clock signal and data signal near the MDI lines
    • Check length matching and impedance matching for MDI lines
    • No vias around the MDI lines
    • Follow the layout checklist in Section 2.2
  • If customer is struggling on conducted immunity IEC61000 4-6 on DP83867 PHY, please program the following script:
    • begin
      008A 010F 
      00C0 0000
      00B3 000C
      0100 1027
      001F 4000
      end

These registers tune the filter inside the PHY to further optimize and filter out high frequency noise and improve the Signal to Noise ratio.