SNVU758 February 2021 TPSM13604H
Wire-loop test points and scope probe sockets are included for digital voltmeters (DVM) or oscilloscope probes to aid in the evaluation of the device. Table 2-1 describes each test point.
For the absolute maximum ratings associated with the features listed in the following table, see the device-specific data sheet.
VIN S+ | Input voltage monitor. Connect the positive lead of a DVM to this point for measuring efficiency. |
VIN S- | Input ground monitor. Connect the negative lead of a DVM to this point for measuring efficiency. |
VOUT S+ | Output voltage monitor. Connect the positive lead of a DVM to this point for measuring efficiency, line regulation, and load regulation. |
VOUT S- | Output ground monitor. Connect the negative lead of a DVM to this point for measuring efficiency, line regulation, and load regulation. |
GND | Ground test point. Connect the negative lead of a DVM to this point when measuring efficiency, line regulation, and load regulation. |
EN | Enable test point. Monitor the Enable signal using this test point. |