SPRUIK4A September 2018 – June 2019 TMS320F280021 , TMS320F280021-Q1 , TMS320F280023 , TMS320F280023-Q1 , TMS320F280023C , TMS320F280025 , TMS320F280025-Q1 , TMS320F280025C , TMS320F280025C-Q1 , TMS320F280040-Q1 , TMS320F280040C-Q1 , TMS320F280041 , TMS320F280041-Q1 , TMS320F280041C , TMS320F280041C-Q1 , TMS320F280045 , TMS320F280048-Q1 , TMS320F280048C-Q1 , TMS320F280049 , TMS320F280049-Q1 , TMS320F280049C , TMS320F280049C-Q1 , TMS320F28075 , TMS320F28075-Q1 , TMS320F28076 , TMS320F28374D , TMS320F28374S , TMS320F28375D , TMS320F28375S , TMS320F28375S-Q1 , TMS320F28376D , TMS320F28376S , TMS320F28377D , TMS320F28377D-Q1 , TMS320F28377S , TMS320F28377S-Q1 , TMS320F28378D , TMS320F28378S , TMS320F28379D , TMS320F28379D-Q1 , TMS320F28379S
C2000 kits may support a solution adapter page, which lets the user launch the compensation designer directly from the solution adapter page. When launched from this page, the compensation designer models the power stage based on the parameters specified on the solution adapter page for inductance, capacitor, and so forth.
The control frequency that is used to calculate the compensator coefficients is also specified on the solution adapter page. The modeled plant can serve as a good starting point in the compensation design process before SFRA is run.
The user can also select SFRA data for the Plant Frequency Response and use the measured data to design the compensator just like when launched in standalone fashion.
NOTE
When Modelled Plant Option is selected the browsed SFRA Data csv file is not used. Before selecting SFRA Data, the user must browse to the appropriate SFRA csv file.