NESY036B September 2021 – April 2023 BQ25125 , LM5123-Q1 , LMR43610 , LMR43610-Q1 , LMR43620 , LMR43620-Q1 , TPS22916 , TPS3840 , TPS62840 , TPS63900 , TPS7A02
指定於 TJ = –40°C 至 +125°C,VIN = VOUT(nom) + 0.5 V 或 2.0 V (取較大者),IOUT = 1 mA,VEN = VIN,及 CIN = COUT = 1 µF (除非另有說明)。TJ = 25°C 的典型值。
參數 | 測試條件 | 最小值 | 典型值 | 最大值 | 單位 | ||
---|---|---|---|---|---|---|---|
額定準確度 | TJ = 25°C,VOUT ≥ 1.5 V,1 µA(1) ≤ IOUT ≤ 1 mA | -1 | 1 | % | |||
TJ = 25°C;VOUT < 1.5 V | -15 | 15 | mV | ||||
在溫度範圍內擁有高精確度 | VOUT ≥ 1.5 V | TJ = –40°C 至 +125°C | -1.5 | 1.5 | % | ||
VOUT ≥ 1.5 V | -20 | 20 | mV | ||||
(ΔVIN) | 線路調整 | VOUT(nom)+ 0.5 V ≤ VIN ≤ 6.0 V (1) | TJ = –40°C 至 +125°C | 5 | mV | ||
ΔVOUT (ΔIOUT) | 線路調整 (2) | 1 mA ≤ IOUT ≤ 200 mA,VIN = VOUT(nom) + 0.5 V (2) | TJ = –40°C 至 +85°C | 20 | 38 | mV | |
TJ = –40°C 至 +125°C | 50 | ||||||
IGND | 接地電流 | IOUT = 0 mA | TJ = 25°C | 25 | 46 | nA | |
TJ = –40°C 至 +85°C | 60 | ||||||
IGND/IOUT | 接地電流與負載電流的比較 | 5 µA ≤ IOUT < 1 mA | TJ = 25°C | 1 | % | ||
1 mA ≤ IOUT < 100 mA | 0.25 | ||||||
IOUT ≥ 100 mA | 0.15 | ||||||
IGND(DO) | 壓降中的接地電流 (3) | IOUT = 0 mA,VIN = 95% x VOUT(nom) | TJ = 25°C | 25 | nA | ||
ISHDN | 關機電流 | VEN = 0 V, 1.5 V ≤ VIN ≤ 5.0 V, TJ = 25°C | TJ = 25°C | 3 | 10 | nA |