10 Revision History
Changes from Revision K (June 2024) to Revision L (July 2024)
- Updated the numbering format for tables, figures, and
cross-references throughout the documentGo
- Updated the typo for Average quiescent current “Serial bus active, SCL frequency = 2.85 MHz” typical value from 30µA to 40µAGo
- Updated the typo for Shutdown current “Serial bus active, SCL frequency = 2.85 MHz” typical value from 25µA to 35µAGo
- Updated empty graphs in the Typical Characteristics sectionGo
- Updated the Temperature Step Response in the Application
Curve section 0.8s to 1.2s due to changing the PCB size of mounted
TMP112 from 0.375×0.437 inches to 0.5×0.5 inchesGo
Changes from Revision J (February 2024) to Revision K (June 2024)
- Updated the numbering format for tables, figures, and
cross-references throughout the documentGo
- Changed the "Conversion time" for TMP112A/B/N throughout the
documentGo
- Changed the active, shutdown, average, and delay quiescent current
for TMP112A/B/N throughout the documentGo
- Added TMP112D (DRL packaged) throughout the
documentGo
- Changed DRL package Thermal Information sectionGo
- Changed "Conversion time" in Electrical Characteristics table for TMP112A/B/N.Go
- Changed and updated Average quiescent current specs for DRL package with DPW package in the Electrical Characteristics table.Go
- Added Average quiescent current MAX to the “Serial bus inactive, CR1 = 0, CR0 = 1” in the Electrical Characteristics table.Go
- Changed Average quiescent current “Serial bus inactive, CR1 = 1, CR0 = 0” for DRL package in Electrical Characteristics table.Go
- Changed Average quiescent current “Serial bus active, SCL frequency = 400 kHz” for DRL package in Electrical Characteristics table.Go
- Added Average quiescent current “Serial bus active, SCL frequency = 1 MHz” for DRL package in Electrical Characteristics table.Go
- Changed Average quiescent current “Serial bus active, SCL frequency = 2.85 MHz” for DRL package in Electrical Characteristics table.Go
- Changed the frequency from 3.4 to 2.85 MHz in the POWER SUPPLY section of the Electrical Characteristics table.Go
- Changed and updated Shutdown current specs for DRL package with DPW package in the Electrical Characteristics table.Go
- Changed Shutdown current “Serial bus inactive” for DRL package in the Electrical Characteristics table.Go
- Changed Shutdown current “Serial bus active, SCL frequency = 400 kHz” for DRL package in Electrical Characteristics table.Go
- Added Shutdown current “Serial bus active, SCL frequency = 1 MHz” for DRL package in Electrical Characteristics table.Go
- Changed Shutdown current “Serial bus active, SCL frequency = 2.85 MHz” for DRL package in Electrical Characteristics table.Go
- Changed Average Quiescent Current vs Temperature, Shutdown Current
vs Temperature, Conversion Time vs Temperature, and Quiescent Current vs Bus
Frequency graphs for TMP112A/B/N in the Typical Characteristics
sectionGo
Changes from Revision I (December 2018) to Revision J (February 2024)
- Updated the numbering format for tables, figures, and cross-references throughout the documentGo
- Changed all instances of legacy terminology to controller and peripheral
where I2C is mentioned Go
- Added X2SON (DPW) package (TMP112Dx) and related information throughout the document Go
- Changed reporting quiescent current from previous Maximum values to Typical values in the Features sectionGo
- Added Device Comparison section Go
- Added Output current (±10mA) to Absolute Maximum Ratings sectionGo
- Added DPW package to Thermal Information sectionGo
- Added Thermal Mass to Thermal Information sectionGo
- Added TMP112Dx (DPW package) information to Electrical Characteristics
Go
- Changed “Timeout time” in description to “Timeout (SCL=GND or SDA=GND)”Go
- Added Fast Mode Plus column to the Timing Requirements tableGo
- Moved the "Two-Wire Timing Diagram" figure from the Two-Wire
Timing Diagrams section to the Specifications section Go
- Added TMP112Dx and TMP110 information to the Advantages of TMP112
Family Versus TMP102 and TMP110 table Go
- Added 0.0625 and -0.0625 row to Temperature column of 12-Bit
Temperature Data Format and 13-Bit Temperature Data Format tables
in the Digital Temperature Output sectionGo
- Updated Address and Alert Variant Device Target Address table in the Serial Bus Address section to include the new package (TMP112Dx) Go
- Changed “Output Transfer Function Diagrams” figure to “Comparator
Mode” and “Interrupt Mode” figures for more clarityGo
- Added Layout Guidelines and Layout Example for new
packageGo
Changes from Revision H (October 2018) to Revision I (December 2018)
- Deleted Absolute Maximum Ratings for output voltage and replaced with pin level informationGo
- Changed input voltage maximum to voltage maximum for SCL, ADD0 and SDA pinsGo
- Added voltage at ALERT pin Absolute Maximum Ratings
Go