SLAA476B February 2011 – July 2019 BQ2040 , BQ2040 , BQ2060A , BQ2060A , BQ2063 , BQ2063 , BQ2083-V1P3 , BQ2083-V1P3 , BQ2084-V143 , BQ2084-V143 , BQ2084-V150 , BQ2084-V150 , BQ2085-V1P3 , BQ2085-V1P3 , BQ20Z40-R1 , BQ20Z40-R1 , BQ20Z70-V160 , BQ20Z70-V160 , BQ20Z80A-V110 , BQ20Z80A-V110 , BQ28400 , BQ28400 , BQ78PL114 , BQ78PL114 , BQ78PL116 , BQ78PL116 , LM5145 , LM5145 , MSP430F5500 , MSP430F5500 , MSP430F5501 , MSP430F5501 , MSP430F5502 , MSP430F5502 , MSP430F5503 , MSP430F5503 , MSP430F5504 , MSP430F5504 , MSP430F5505 , MSP430F5505 , MSP430F5506 , MSP430F5506 , MSP430F5507 , MSP430F5507 , MSP430F5508 , MSP430F5508 , MSP430F5509 , MSP430F5509 , MSP430F5510 , MSP430F5510 , TPS40057 , TPS40057 , TPS40170 , TPS40170
Table 3 represents the mapping between the MSP430F5510 PWM duty cycle and the voltage output from the DC/DC converter. The PWM frequency is 20 kHz and modifying the PWM duty cycle for the voltage input changes the voltage output of the DC/DC converter. Pulling the PWM signals LOW causes the DC/DC converter to switch off and stop delivering power to the battery.
Duty Cycle
(%) |
PWM Average Voltage
(V) |
Average Output Voltage
(V) |
---|---|---|
0 | 0 | 0 |
10.78 | 0.335 | 5.5 |
24.71 | 0.791 | 12.6 |
32.94 | 1.054 | 16.8 |
68.6 | 2.196 | 35 (maximum allowed with TPS40054 Power Stage Board) |
100.0 | 3.200 | 51 (maximum allowed with TPS40170 Power Stage Board) |
Sample Calculation Example: