OCA: |
1 = |
Over Charged Alarm(1) |
TCA: |
1 = |
Terminate Charge Alarm(1) |
OTA: |
1 = |
Over Temperature Alarm(1) |
TDA: |
1 = |
Terminate Discharge Alarm |
RCA: |
Remaining Capacity Alarm |
|
1 = |
Remaining Capacity Alarm is set [see: SBS:RemainingCapacityAlarm(0x01)] |
RTA: |
Remaining Time Alarm |
|
1 = |
Remaining Time Alarm is set [see: SBS:RemainingTimeAlarm(0x02)] |
INIT: |
1 = |
Initialization. This flag is cleared approximately 1 second after device reset, after all SBS parameters have been measured and updated. |
DSG: |
Discharging |
|
0 = |
bq20z90 or bq20z95 is in charging mode |
|
1 = |
bq20z90 or bq20z95 is in discharging mode, relaxation mode, or valid charge termination has occurred (see the Gas Gauging section in bq20z90-V1.50 + bq29330, bq20z95 Technical Reference (SLUU264) [10] |
FC: |
1 = |
Fully Charged(1) |
FD: |
1 = |
Fully Discharged |
EC3, EC2, EC1, EC0: Error Code, returns status of processed SBS function |
|
0,0,0,0 = |
OK |
bq20z90 or bq20z95 processed the function code with no errors detected. |
|
0,0,0,1 = |
BUSY |
bq20z90 or bq20z95 is unable to process the function code at this time. |
|
0,0,1,0 = |
Reserved |
bq20z90 or bq20z95 detected an attempt to read or write to a function code reserved by this version of the specification or bq20z90 or bq20z95 detected an attempt to access an unsupported optional manufacturer function code. |