SLVA954B October   2021  – August 2022 ESD751-Q1 , TPD1E01B04-Q1 , TPD1E05U06-Q1 , TPD1E10B06-Q1 , TPD1E10B09-Q1 , TPD2E001-Q1 , TPD2E2U06-Q1 , TPD4E001-Q1 , TPD4E02B04-Q1 , TSD05C

 

  1.   Abstract
  2.   Trademarks
  3. 1ISO 10605 Overview
  4. 2ISO 10605 ESD Waveforms and Test Parameters
  5. 3ISO 10605 Bench Setup
  6. 4How to Interpret Test Data and Choose the Correct Protection
  7. 5Conclusions
  8. 6Revision History

Conclusions

Testing and verifying transient immunity is a vital component in ensuring the reliability of modern electronic components, and ISO 10605 provides the guidelines for automotive ESD testing.

While ISO 10605 standard is similar to the IEC 61000-4-2 standard, it has several key differences:

  1. The generator is grounded to the table instead of the floor to simulate the isolated environment of a vehicle.
  2. The test is performed at different resistance values to simulate the discharge of a body directly and through a metal object. It is also performed at different capacitances to simulate a discharge both inside and outside the vehicle.
While there are a variety of other differences, ISO 10605 is quite similar to IEC 61000-4-2, and it is the industry standard for ESD protection devices in automotive applications.