SPRUJ42E March 2022 – October 2024 AM2631 , AM2631-Q1 , AM2632 , AM2632-Q1 , AM2634 , AM2634-Q1
PRODUCTION DATA
ECC Control Register.
Return to Summary Table
Instance Name | Physical Address |
---|---|
R5SS0 | 5300 3014h |
R5SS1 | 5300 7014h |
31 | 30 | 29 | 28 | 27 | 26 | 25 | 24 |
RESERVED | |||||||
NONE | |||||||
0h | |||||||
23 | 22 | 21 | 20 | 19 | 18 | 17 | 16 |
RESERVED | |||||||
NONE | |||||||
0h | |||||||
15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 |
RESERVED | CHECK_SVBUS_TIMEOUT | ||||||
NONE | R/W | ||||||
0h | 1h | ||||||
7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
CHECK_PARITY | ERROR_ONCE | FORCE_N_ROW | FORCE_DED | FORCE_SEC | ENABLE_RMW | ECC_CHECK | ECC_ENABLE |
R/W | R/W | R/W | R/W | R/W | R/W | R/W | R/W |
1h | 0h | 0h | 0h | 0h | 1h | 1h | 1h |
Bit | Field | Type | Reset | Description |
---|---|---|---|---|
31:9 | RESERVED | NONE | 0h | Reserved |
8 | CHECK_SVBUS_TIMEOUT | R/W | 1h | check for svbus timeout errors |
7 | CHECK_PARITY | R/W | 1h | check for parity errors |
6 | ERROR_ONCE | R/W | 0h | Force Error only once |
5 | FORCE_N_ROW | R/W | 0h | Force Error on any RAM read |
4 | FORCE_DED | R/W | 0h | Force Double Bit Error |
3 | FORCE_SEC | R/W | 0h | Force Single Bit Error |
2 | ENABLE_RMW | R/W | 1h | Enable rmw |
1 | ECC_CHECK | R/W | 1h | Enable ECC check |
0 | ECC_ENABLE | R/W | 1h | Enable ECC |