AFE4300

ACTIVO

Circuito frontal analógico (AFE) para la medición de peso y la composición corporal

Detalles del producto

Applications Body composition measurements for weight scales Number of input channels 2 Resolution (bps) 16 Number of LEDs 0 Interface type SPI Operating temperature range (°C) 0 to 70 Rating Catalog
Applications Body composition measurements for weight scales Number of input channels 2 Resolution (bps) 16 Number of LEDs 0 Interface type SPI Operating temperature range (°C) 0 to 70 Rating Catalog
LQFP (PN) 80 196 mm² 14 x 14
  • Weight-scale front-end:
    • Supports up to four load cell inputs
    • On-chip load cell 1.7-V excitation voltage for ratiometric measurement
    • 68-nVrms Input-Referred noise
      (0.1 Hz to 2 Hz)
    • Best-fit linearity: 0.01% of full-scale
    • Weight-scale measurement : 540 µA
  • Body composition front-end:
    • Supports up to three tetra-polar complex impedance measurements
    • 6-Bit, 1-MSPS sine-wave generation digital-to-analog converter (DAC)
    • 247.5-µArms, ±20% Excitation source
    • 0.1-Ω Measurement RMS noise in 2-Hz BW
    • Body composition measurement : 970 µA
  • Analog-to-digital converter (ADC):
    • 16 Bits, 860 SPS
    • Supply current: 110 µA
  • Weight-scale front-end:
    • Supports up to four load cell inputs
    • On-chip load cell 1.7-V excitation voltage for ratiometric measurement
    • 68-nVrms Input-Referred noise
      (0.1 Hz to 2 Hz)
    • Best-fit linearity: 0.01% of full-scale
    • Weight-scale measurement : 540 µA
  • Body composition front-end:
    • Supports up to three tetra-polar complex impedance measurements
    • 6-Bit, 1-MSPS sine-wave generation digital-to-analog converter (DAC)
    • 247.5-µArms, ±20% Excitation source
    • 0.1-Ω Measurement RMS noise in 2-Hz BW
    • Body composition measurement : 970 µA
  • Analog-to-digital converter (ADC):
    • 16 Bits, 860 SPS
    • Supply current: 110 µA

The AFE4300 is a low-cost analog front-end incorporating two separate signal chains: one chain for weight-scale (WS) measurement and the other for body composition measurement (BCM) analysis. A 16-bit, 860-SPS analog-to-digital converter (ADC) is multiplexed between both chains. The weight measurement chain includes an instrumentation amplifier (INA) with the gain set by an external resistor, followed by a 6-bit digital-to-analog converter (DAC) for offset correction, and a circuit to drive the external bridge/load cell with a fixed 1.7 V for ratiometric measurements.

The AFE4300 can also measure body composition by applying a sinusoidal current into the body. The sinusoidal current is generated with an internal pattern generator and a 6-bit, 1-MSPS DAC. A voltage-to-current converter applies this sinusoidal current into the body, between two terminals. The voltage created across these two terminals as a result of the impedance of the body is measured back with a differential amplifier, rectified, and the amplitude is extracted and measured by the 16-bit ADC.

The AFE4300 operates from 2 V to 3.6 V, is specified from 0°C to +70°C, and is available in a LQFP-80 package.

The AFE4300 is a low-cost analog front-end incorporating two separate signal chains: one chain for weight-scale (WS) measurement and the other for body composition measurement (BCM) analysis. A 16-bit, 860-SPS analog-to-digital converter (ADC) is multiplexed between both chains. The weight measurement chain includes an instrumentation amplifier (INA) with the gain set by an external resistor, followed by a 6-bit digital-to-analog converter (DAC) for offset correction, and a circuit to drive the external bridge/load cell with a fixed 1.7 V for ratiometric measurements.

The AFE4300 can also measure body composition by applying a sinusoidal current into the body. The sinusoidal current is generated with an internal pattern generator and a 6-bit, 1-MSPS DAC. A voltage-to-current converter applies this sinusoidal current into the body, between two terminals. The voltage created across these two terminals as a result of the impedance of the body is measured back with a differential amplifier, rectified, and the amplitude is extracted and measured by the 16-bit ADC.

The AFE4300 operates from 2 V to 3.6 V, is specified from 0°C to +70°C, and is available in a LQFP-80 package.

Descargar
Solicitar más información

La hoja de datos completa está disponible. Solicitar ahora

Documentación técnica

star =Principal documentación para este producto seleccionada por TI
No se encontraron resultados. Borre su búsqueda y vuelva a intentarlo.
Ver todo 1
Tipo Título Fecha
* Data sheet AFE4300 Low-Cost, Integrated Analog Front-End for Weight-Scale and Body Composition Measurement datasheet PDF | HTML 16 ago 2019

Pedidos y calidad

Información incluida:
  • RoHS
  • REACH
  • Marcado del dispositivo
  • Acabado de plomo/material de la bola
  • Clasificación de nivel de sensibilidad a la humedad (MSL) / reflujo máximo
  • Estimaciones de tiempo medio entre fallas (MTBF)/fallas en el tiempo (FIT)
  • Contenido del material
  • Resumen de calificaciones
  • Monitoreo continuo de confiabilidad
Información incluida:
  • Lugar de fabricación
  • Lugar de ensamblaje

Soporte y capacitación

Foros de TI E2E™ con asistencia técnica de los ingenieros de TI

El contenido lo proporcionan “tal como está” TI y los colaboradores de la comunidad y no constituye especificaciones de TI. Consulte los términos de uso.

Si tiene preguntas sobre la calidad, el paquete o el pedido de productos de TI, consulte el soporte de TI. ​​​​​​​​​​​​​​