JAJS137I NOVEMBER 2006 – November 2016 DCH010505D , DCH010505S , DCH010512D , DCH010512S , DCH010515D , DCH010515S
PRODUCTION DATA.
MIN | MAX | UNIT | ||
---|---|---|---|---|
Input voltage (5-V input models) | 7 | V | ||
Storage temperature, Tstg | –55 | 125 | °C |
VALUE | UNIT | |||
---|---|---|---|---|
V(ESD) | Electrostatic discharge | Human-body model (HBM), per ANSI/ESDA/JEDEC JS-001(1) | ±2000 | V |
Charged-device model (CDM), per JEDEC specification JESD22-C101(2) | ±250 |
MIN | MAX | UNIT | ||
---|---|---|---|---|
+VI | Input voltage | 4.5 | 5.5 | V |
TA | Operating ambient temperature | –40 | 85 | °C |
THERMAL METRIC(1) | DCH01 SERIES | UNIT | ||
---|---|---|---|---|
EDJ (SIP-SINGLE) |
EDJ (SIP-DUAL) |
|||
7 PINS | 7 PINS | |||
RθJA | Junction-to-ambient thermal resistance | 66 | 66 | °C/W |
ψJT | Junction-to-top characterization parameter | 3 | 3 | °C/W |
ψJB | Junction-to-board characterization parameter | 66 | 66 | °C/W |
PARAMETER | TEST CONDITIONS | MIN | TYP | MAX | UNIT | ||
---|---|---|---|---|---|---|---|
VI | Input voltage | All devices nominal | 5 | V | |||
VNOM | Output voltage | 100% load(1) | DCH010505S | 5.1 | V | ||
DCH010505D | ±5.2 | ||||||
DCH010512S | 12.4 | ||||||
DCH010512D | ±12.5 | ||||||
DCH010515S | 15.2 | ||||||
DCH010515D | ±15.3 | ||||||
Load regulation | 10% to 100% load(2) | DCH010505S | 10% | ||||
DCH010505D | 9% | ||||||
DCH010512S | 6% | ||||||
DCH010512D | 5% | ||||||
DCH010515S | 6% | ||||||
DCH010515D | 5% | ||||||
Output ripple | 100% LOAD(1) | DCH010505S | 35 | mVPP | |||
DCH010505D | 20 | ||||||
DCH010512S | 18 | ||||||
DCH010512D | 19 | ||||||
DCH010515S | 31 | ||||||
DCH010515D | 22 | ||||||
IQ | Input current | No load; 0% load | DCH010505x | 60 | mA | ||
DCH010512x | 65 | ||||||
DCH010515x | 65 | ||||||
Efficiency | 100% load(1) | DCH010505x | 72% | ||||
DCH010512S | 74% | ||||||
DCH010512D | 75% | ||||||
DCH010515S | 75% | ||||||
DCH010515D | 76% | ||||||
CISO | Barrier capacitance | DCH010505x & DCH010515x | 3 | pF | |||
DCH010512x | 4 | ||||||
Output power | 100% full load | 1(3) | W | ||||
Over current duration(3) | 1 | sec | |||||
Input voltage on VI | –10% | 10% | |||||
Isolation voltage | 100% tested for 1 second | 3.5 | kVDC | ||||
Line regulation | 1% change in VI | 1% | |||||
Switching frequency (fSW) | 70 | kHz | |||||
Calculated reliability | Per Telcordia SR-332, 50% stress, TA = 40°C |
Single output | 18 | FITS | |||
Dual output | 22 |