SPRADG6 April   2024 F28M36H33B2 , SM320LF2407A-EP , TMS320C28341 , TMS320C28343 , TMS320F2800132 , TMS320F2800133 , TMS320F2800135 , TMS320F2800137 , TMS320F2800152-Q1 , TMS320F2800153-Q1 , TMS320F2800154-Q1 , TMS320F2800155-Q1 , TMS320F2800156-Q1 , TMS320F2800157 , TMS320F2800157-Q1 , TMS320F280021 , TMS320F280021-Q1 , TMS320F280023 , TMS320F280023-Q1 , TMS320F280023C , TMS320F280025 , TMS320F280025-Q1 , TMS320F280025C , TMS320F280025C-Q1 , TMS320F280033 , TMS320F280034 , TMS320F280034-Q1 , TMS320F280036-Q1 , TMS320F280036C-Q1 , TMS320F280037 , TMS320F280037-Q1 , TMS320F280037C , TMS320F280037C-Q1 , TMS320F280038-Q1 , TMS320F280038C-Q1 , TMS320F280039 , TMS320F280039-Q1 , TMS320F280039C , TMS320F280039C-Q1 , TMS320F280040-Q1 , TMS320F280040C-Q1 , TMS320F280041 , TMS320F280041-Q1 , TMS320F280041C , TMS320F280041C-Q1 , TMS320F280045 , TMS320F280048-Q1 , TMS320F280048C-Q1 , TMS320F280049 , TMS320F280049-Q1 , TMS320F280049C , TMS320F280049C-Q1 , TMS320F28035-EP , TMS320F28050 , TMS320F28051 , TMS320F28052 , TMS320F28052-Q1 , TMS320F28052M-Q1 , TMS320F28054 , TMS320F28054-Q1 , TMS320F28062F-Q1 , TMS320F28064 , TMS320F28066-Q1 , TMS320F28068M , TMS320F28069F-Q1 , TMS320F28075 , TMS320F28075-Q1 , TMS320F28076 , TMS320F2810 , TMS320F2811 , TMS320F28333 , TMS320F28374D , TMS320F28374S , TMS320F28375D , TMS320F28375S , TMS320F28375S-Q1 , TMS320F28376D , TMS320F28376S , TMS320F28377D , TMS320F28377D-EP , TMS320F28377D-Q1 , TMS320F28377S , TMS320F28377S-Q1 , TMS320F28378D , TMS320F28378S , TMS320F28379D , TMS320F28379D-Q1 , TMS320F28379S , TMS320F28384D , TMS320F28384D-Q1 , TMS320F28384S , TMS320F28384S-Q1 , TMS320F28386D , TMS320F28386D-Q1 , TMS320F28386S , TMS320F28386S-Q1 , TMS320F28388D , TMS320F28388S , TMS320F28P550SJ , TMS320F28P559SJ-Q1 , TMS320F28P650DK , TMS320F28P659DK-Q1

 

  1.   1
  2.   Abstract
  3.   Trademarks
  4. 1C2000 Power Supply and Monitoring Solution
  5. 2Power Supply Solution for Safety Applications
    1. 2.1 ASIL-D Requirements
      1. 2.1.1 PMIC Solution
    2. 2.2 ASIL-B: Requirements
      1. 2.2.1 PMIC Solution
      2. 2.2.2 Discrete Solution
  6. 3Power Supply Solution for Non-Safety Applications
  7. 4Summary
  8. 5References

ASIL-D Requirements

ASLIL-D functional safety has several voltage monitoring and CPU health requirements that are beyond the scope of this application report. There are various methods to meet these requirements. One approach is to use a power management IC that not only delivers power to the MCU, but also integrates various voltage monitoring and watchdog features needed to meet ASIL-D requirements. The PMIC selected to meet the ASIL-D requirements should meet all the following criteria.