SWRA670A April 2020 – October 2022 CC1350 , CC1352P , CC1352R , CC2400 , CC2420 , CC2430 , CC2500 , CC2520 , CC2530 , CC2538 , CC2540 , CC2541 , CC2543 , CC2544 , CC2545 , CC2564 , CC2590 , CC2591 , CC2592 , CC2620 , CC2630 , CC2640 , CC2650 , CC2652P , CC2652R , CC2652R7 , CC2652RSIP , CC3100 , CC3120 , CC3135 , CC3135MOD , CC3200 , CC3200MOD , CC3220MOD , CC3220MODA , CC3220R , CC3220S , CC3220SF , CC3230S , CC3230SF , CC3235MODAS , CC3235MODASF , CC3235MODS , CC3235MODSF , CC3235S , CC3235SF , WL1801MOD , WL1805MOD , WL1807MOD , WL1831
The purpose of this test is intended to assess the ability of the EUT to operate as intended in the presence of a radio frequency disturbance on the input/output ports. This test should be performed on the AC mains power port (if any) of radio equipment and associated ancillary equipment. This test should be additionally performed on signal ports, wired network ports, control ports, and DC power ports, of radio equipment and associated ancillary equipment, if the cables may be longer than 3 m.
Where this test is not carried out on any port because it is not intended to be used with cables longer than 3 m, a list of the ports, which were not tested for this reason, should be included in the test report.
The test method should be in accordance with CENELEC EN 61000-4-6, clauses 6 and 8.
The EUT should meet the performance criteria for continuous phenomena (see Section 7.6), when it is tested with the following requirements: