BQ76PL536 不建議用於新設計
此產品將繼續向現有客戶提供。新設計應考量替代產品。
open-in-new 比較替代產品
引腳對引腳且具備與所比較裝置相同的功能
BQ76PL536A 現行 適用工業電池組的 3 至 6 串聯芯鋰離子電池監控器和二次保護 bq76PL536 is not recommended for new designs. Consider bq76PL536A for all new designs since this is a pin and function compatible device with improved communication functionality, noise immunity and ADC performance.

產品詳細資料

Features Cell balancing, LDO output, One-Time Programmable (OTP) memory, Overtemperature protection, Overvoltage protection, Precision ADC, SPI, Undervotlage protection Device type Cell monitor and balancer Operating temperature range (°C) -40 to 85 Rating Automotive Communication interface SPI
Features Cell balancing, LDO output, One-Time Programmable (OTP) memory, Overtemperature protection, Overvoltage protection, Precision ADC, SPI, Undervotlage protection Device type Cell monitor and balancer Operating temperature range (°C) -40 to 85 Rating Automotive Communication interface SPI
HTQFP (PAP) 64 144 mm² 12 x 12
  • 3 to 6 Series Cell Support, All Chemistries
  • Hot-Pluggable
  • High-Speed SPI for Data Communications
  • Stackable Vertical Interface
  • No Isolation Components Required Between ICs
  • Industrial Temperature Range, –40°C to 85°C
  • High-Accuracy Analog-to-Digital Converter (ADC):
    • ±3 mV Typical accuracy
    • 14-Bit Resolution, 6-µs Conversion Time
    • Nine ADC Inputs: 6 Cell Voltages, 1 Six-Cell Brick Voltage,
      2 Temperatures, 1 General-Purpose Input
    • Dedicated Pins for Synchronizing Measurements
  • Configuration Data Stored in ECC-OTP Registers
  • Built-In Comparators (Secondary Protector) for:
    • Over- and Undervoltage Protection
    • Overtemperature Protection
    • Programmable Thresholds and Delay Times
    • Dedicated Fault Output Signals for OV, UV, OT
  • Cell Balancing Control Outputs With Safety Timeout
    • Balance Current Set by External Components
  • Supply Voltage Range from 6 V to 30 V Continuous and 36 V Peak
  • Low Power:
    • Typical 12-µA Sleep, 45-µA Idle
  • Integrated Precision 5-V, 3-mA LDO
  • APPLICATIONS
    • Uninterruptible Power Systems (UPS)
    • E-Bike and E-Scooter
    • Large-Format Battery Systems
    • Electric and Hybrid Electric Vehicles

  • 3 to 6 Series Cell Support, All Chemistries
  • Hot-Pluggable
  • High-Speed SPI for Data Communications
  • Stackable Vertical Interface
  • No Isolation Components Required Between ICs
  • Industrial Temperature Range, –40°C to 85°C
  • High-Accuracy Analog-to-Digital Converter (ADC):
    • ±3 mV Typical accuracy
    • 14-Bit Resolution, 6-µs Conversion Time
    • Nine ADC Inputs: 6 Cell Voltages, 1 Six-Cell Brick Voltage,
      2 Temperatures, 1 General-Purpose Input
    • Dedicated Pins for Synchronizing Measurements
  • Configuration Data Stored in ECC-OTP Registers
  • Built-In Comparators (Secondary Protector) for:
    • Over- and Undervoltage Protection
    • Overtemperature Protection
    • Programmable Thresholds and Delay Times
    • Dedicated Fault Output Signals for OV, UV, OT
  • Cell Balancing Control Outputs With Safety Timeout
    • Balance Current Set by External Components
  • Supply Voltage Range from 6 V to 30 V Continuous and 36 V Peak
  • Low Power:
    • Typical 12-µA Sleep, 45-µA Idle
  • Integrated Precision 5-V, 3-mA LDO
  • APPLICATIONS
    • Uninterruptible Power Systems (UPS)
    • E-Bike and E-Scooter
    • Large-Format Battery Systems
    • Electric and Hybrid Electric Vehicles

The bq76PL536 is a stackable three to six series cell lithium-ion battery pack protector and analog front end (AFE) that incorporates a precision analog-to-digital converter (ADC); independent cell voltage and temperature protection; cell balancing, and a precision 5-V regulator to power user circuitry.

The bq76PL536 integrates a voltage translation and precision analog-to-digital converter system to measure battery cell voltages with high accuracy and speed.

The bq76PL536 provides full protection (secondary protection) for overvoltage, undervoltage, and overtemperature conditions. When safety thresholds are exceeded, the bq76PL536 sets the FAULT output. No external components are needed to configure or enable the protection features.

Cell voltage and temperature protection functions are independent of the ADC system. Programmable protection thresholds and detection delay times are stored in Error Check/Correct (ECC) OTP EPROM, which increases the flexibility and reliability of the battery management system.

The bq76PL536 is intended to be used with a host controller to maximize the functionality of the battery management system. However, the protection functions do not require a host controller.

The bq76PL536 can be stacked vertically to monitor up to 192 cells without additional isolation components between ICs. A high-speed serial peripheral interface (SPI) bus operates between each bq76PL536 to provide reliable communications through a high-voltage battery cell stack.

The host microcontroller controls cell balancing of individual cells by setting the registers (via SPI) which control the appropriate CBx outputs. These outputs can be turned off via the same control, or automatically by the internal programmable safety timer. The balancing bypass current is set via an external series resistor and FET.

The bq76PL536 is a stackable three to six series cell lithium-ion battery pack protector and analog front end (AFE) that incorporates a precision analog-to-digital converter (ADC); independent cell voltage and temperature protection; cell balancing, and a precision 5-V regulator to power user circuitry.

The bq76PL536 integrates a voltage translation and precision analog-to-digital converter system to measure battery cell voltages with high accuracy and speed.

The bq76PL536 provides full protection (secondary protection) for overvoltage, undervoltage, and overtemperature conditions. When safety thresholds are exceeded, the bq76PL536 sets the FAULT output. No external components are needed to configure or enable the protection features.

Cell voltage and temperature protection functions are independent of the ADC system. Programmable protection thresholds and detection delay times are stored in Error Check/Correct (ECC) OTP EPROM, which increases the flexibility and reliability of the battery management system.

The bq76PL536 is intended to be used with a host controller to maximize the functionality of the battery management system. However, the protection functions do not require a host controller.

The bq76PL536 can be stacked vertically to monitor up to 192 cells without additional isolation components between ICs. A high-speed serial peripheral interface (SPI) bus operates between each bq76PL536 to provide reliable communications through a high-voltage battery cell stack.

The host microcontroller controls cell balancing of individual cells by setting the registers (via SPI) which control the appropriate CBx outputs. These outputs can be turned off via the same control, or automatically by the internal programmable safety timer. The balancing bypass current is set via an external series resistor and FET.

下載

技術文件

star =TI 所選的此產品重要文件
找不到結果。請清除您的搜尋條件,然後再試一次。
檢視所有 1
類型 標題 日期
* Data sheet 3 to 6 Series Cell Lithium-Ion Battery Monitor and Secondary Protection IC datasheet (Rev. A) 2010年 7月 7日

訂購與品質

內含資訊:
  • RoHS
  • REACH
  • 產品標記
  • 鉛塗層/球物料
  • MSL 等級/回焊峰值
  • MTBF/FIT 估算值
  • 材料內容
  • 認證摘要
  • 進行中持續性的可靠性監測
內含資訊:
  • 晶圓廠位置
  • 組裝地點