SLYA036B July 2018 – November 2021 DRV5053 , DRV5053-Q1 , DRV5055 , DRV5055-Q1 , DRV5056 , DRV5056-Q1 , DRV5057 , DRV5057-Q1
Linear Hall effect sensors measure the strength of a magnetic field and output a voltage proportional to that measurement. Based on the degree range and resolution needed, one or more linear Hall sensors can be used to determine the magnet direction. This application report covers angle measurements using no calibration, peak calibration, lookup table calibration, and a hybrid method of both the peak calibrated and lookup table methods.