SBAA541 December 2022 AMC1202 , AMC1302 , AMC1306M05 , AMC22C11 , AMC22C12 , AMC23C10 , AMC23C11 , AMC23C12 , AMC23C14 , AMC23C15 , AMC3302 , AMC3306M05
The goal of the current control loops of the AC/DC stage is to keep the currents detected by the MCU under control without determining the real currents in the system. If the measurement does not match the reality, there is an unwanted power disturbance in the system caused by the gain error, which is expressed in Equation 8.
where
The power disturbance is a function of the converter power between the AC and DC stage and reaches the maximum when the maximum power is requested by the AC/DC converter. Furthermore, Equation 8 can be divided in two parts as in Equation 6 and Equation 7.
where
Impacts of these power disturbances in the DC and AC sides are investigated by observing the voltage control loops together with the imperfection that was detected.