Changes from Revision L (February 2023) to Revision M (June 2024)
- Added ND device information to the data sheetGo
- Changed the temperature condition statement in the Typical
Characteristics section headerGo
- Added graphs to the Typical Characteristics section to include the
DRV5013ND and DRV5013FA device versionsGo
- Added text to the Overview section to highlight the
differences between the inverted and non-inverted output device
versionsGo
- Changed the Field Direction Definition section Go
- Added text to the Device Output section to highlight the differences
between the inverted and non-inverted output device versionsGo
- Added text to the Power-On Time section to highlight the differences
between the inverted and non-inverted output device versionsGo
Changes from Revision K (August 2019) to Revision L (February 2023)
- Updated the numbering format for tables, figures, and
cross-references throughout the documentGo
- Changed table title from: Device Information to: Package
InformationGo
- Moved the Power Supply Recommendations and Layout
sections to the Application and Implementation sectionGo
Changes from Revision J (June 2019) to Revision K (August 2019)
- Changed TJ to show existing range is for Q version device in the Absolute Maximum Ratings tableGo
- Added E version for TJ to the Absolute Maximum Ratings tableGo
- Changed TA to show existing range is for Q version device in the Recommended Operating Conditions tableGo
- Added E version for TA to the Recommended Operating Conditions tableGo
- Changed ICC test condition for TA from 125 to TA,MAX to highlight the differences between the E and Q version devicesGo
- Changed rDS(on) test condition for TA from 125 to TA,MAX to highlight the difference between the E and Q version devicesGo
- Changed all test conditions for TA max from 125 to TA,MAX to highlight difference between the E and Q devicesGo
- Added new condition statement to Typical Characteristics
sectionGo
- Added data up to 150°C to Figure 1, Figure 2, Figure 4, Figure 6, Figure 8,
and Figure 10Go
Changes from Revision I (August 2018) to Revision J (June 2019)
- Added TO-92 (LPE) package to data sheet Go
Changes from Revision H (September 2016) to Revision I (August 2018)
- Changed Power Supply Recommendations section Go
Changes from Revision G (August 2016) to Revision H (September 2016)
- Changed the power-on time for the FA version in the Electrical Characteristics tableGo
Changes from Revision F (May 2016) to Revision G (August 2016)
- Changed the maximum BOP and the minimum BRP for the FA version in the Magnetic Characteristics tableGo
- Added the Layout sectionGo
Changes from Revision E (February 2016) to Revision F (May 2016)
- Revised preliminary limits for the FA versionGo
Changes from Revision D (December 2015) to Revision E (February 2016)
- Added the FA device optionGo
- Added the typical bandwidth value to Magnetic Characteristics tableGo
Changes from Revision C (September 2014) to Revision D (June 2015)
- Corrected body size of SOT-23 package and SIP package name to TO-92 Go
- Added BMAX to Absolute Maximum Ratings
Go
- Removed table note from junction temperatureGo
- Added Community Resources
Go
- Updated package tape and reel options for M and blank Go
Changes from Revision B (July 2014) to Revision C (September 2014)
- Updated high sensitivity options Go
- Changed the max operating junction temperature to 150°CGo
- Updated the output rise and fall time typical values and removed max values in Switching Characteristics
Go
- Updated the values in Magnetic Characteristics
Go
- Updated all Typical Characteristics graphs Go
- Updated Equation 4
Go
- Updated
Device Nomenclature
Go
Changes from Revision A (March 2014) to Revision B (June 2014)
- Changed IOCP MIN and MAX values from 20 and 40 to 15 and 45, respectively, in the Electrical Characteristics
Go
- Changed the MIN value for the ±2.3 mT BRP parameter from –4 to –5 in the Magnetic Characteristics tableGo
- Updated the hysteresis values for each device option in the Magnetic Characteristics tableGo
Changes from Revision * (March 2014) to Revision A (March 2014)
- Changed all references to Hall IC to Hall Effect Sensor Go
- Changed RPM Meter to Tachometers in the
Applications list Go
- Changed the power-on value from 50 to 35 µs in the Features
list Go
- Changed the type of the OUT terminal from OD to Output in the Pin
Functions table Go
- Deleted Output pin current and changed VCCmax to VCC after the voltage ramp rate for the supply voltageGo
- Changed RO to R1 in the test conditions for tr and tf in the Switching Characteristics tableGo
- Added the bandwidth parameter to Magnetic Characteristics tableGo
- Changed the MIN value for the ±2.3 mt BRP parameter from +2.3 to –2.3 in the Magnetic Characteristics tableGo
- Deleted condition statement from the Typical Characteristics and
changed all TJ to TA in the graph conditions Go
- Deleted Number from the Power-On Time case names; added conditions to
captions of case timing diagrams Go
- Added the R1 tradeoff and lower current text after the equation in the
Output Stage section Go
- Added the C2 not required for most applications text after the second
equation in the Output Stage sectionGo
- Changed IO to ISINK in condition statement of FET overload fault condition in Reverse Supply Protection sectionGo