Our integrated circuits and reference designs help you create efficient central processing unit (CPU) modules whether they are run by programmable logic controller (PLC) code, C code or by software on a high-level operating system. We have the ingredients to assess available performances, latencies, heat dissipation, reliability data and wiring protection.

Design requirements

CPU (PLC controller) systems often require:

  • Artificial intelligence (AI) edge processing, time-sensitive networking (TSN) and OPC Unified Architecture.
  • Scalable solutions for processing and industrial networking.
  • Functional-safety readiness, robustness and/or EMI/EMC resilience.

Block diagram

Find products and reference designs for your system.

Micro programmable controller

115/23VAC 115/23VAC Comms Comms Wireless Interface Wireless Interface WiFi WiFi Signal Isolation Signal Isolation Data Isolation Data Isolation Signal Input/Output Protection Signal Input/Output Protection TVs /ESD TVs /ESD Wired Interface Wired Interface Ethernet / RS-485 / LVDS / USB Ethernet / RS-485 / LVDS / USB Backplane Backplane ... ... Digital Processing Digital Processing ARM ARM BUS ASIC BUSASIC Self-Diagnostics/Monitoring Self-Diagnostics/Monitoring Temperature Sensor Temperature Sensor Supervisor Supervisor Energy Storage Energy Storage Battery or Supercap Charger Battery or Supercap Charger Gas Gauge Gas Gauge Non-Isolated DC/DC Power Supply Non-Isolated DC/DC Power Supply DC/DC DC/DC LDO LDO PMIC PMIC ARM ARM Analog Front-End Analog Front-End High-side or low-side switches High-side or low-side switches Isolated IEC61131-2 Inputs Isolated IEC61131-2 Inputs Output User Interface Output User Interface LED Driver LED Driver Input User Interface Input User Interface Keyboard Scanner / touch buttons Keyboard Scanner / touch buttons Isolated AC/DC Power Supply Isolated AC/DC Power Supply Isolated AC/DC Isolated AC/DC

Self-diagnostics/monitoring

close

To ensure correct functioning of the module, it is necessary to monitor the temperature and in some cases of the humidity on the module. Depending on the internal system setup and board size, multiple sensors may be used.

View allchevron-down
Power management (6)
Supervisor & reset ICs
  • TPS3899Nanopower supervisor with programmable sense and reset delay
    Data sheet: PDF | HTML
  • TPS3840Nanopower high-input voltage supervisor with manual reset and programmable-reset time delay
    Data sheet: PDF | HTML
  • TPS3808E600nA ultra-low quiescent current supervisor with programmable delay and manual reset
    Data sheet: PDF | HTML
  • TLV809ELow-power voltage supervisor (reset IC) with active-low push-pull output
    Data sheet: PDF | HTML
  • TPS3765-V window supervisor with ultra-low quiescent current and time-delay function
    Data sheet: PDF | HTML
  • TLV840Low-voltage supervisor with adjustable-reset time delay and manual reset
    Data sheet: PDF | HTML
Amplifiers (6)
Comparators
  • LM239Quad differential comparator, commercial grade
    Data sheet: PDF | HTML
  • LM2901AVPrecision quad differential comparator
    Data sheet: PDF | HTML
  • LM2903Dual differential comparator
    Data sheet: PDF | HTML
  • TLV7041Nanopower, small size comparator with open-drain output
    Data sheet: PDF | HTML
  • LM2901B36-V, quad differential standard comparator
    Data sheet: PDF | HTML
  • LM2901-NLow offset, quad differential comparator
    Data sheet: PDF | HTML

    Technical documentation

    View all 17
    No results found. Please clear your search and try again.
    Type Title Date
    White paper Time Sensitive Networking for Industrial Automation (Rev. C) 31 Jul 2023
    Technical article How to select the right industrial Ethernet standard: PROFINET PDF | HTML 28 Sep 2023
    White paper EtherNet/IP on TI's Sitara AM335x Processors (Rev. D) 28 Jul 2020
    White paper EtherCAT® on Sitara™ Processors (Rev. I) 28 Jul 2020
    Technical article How to select the right industrial Ethernet standard: Sercos III PDF | HTML 22 Sep 2023
    Application note AM335x Reliability Considerations in PLC Applications (Rev. A) 22 Oct 2015
    White paper Selecting the right industrial communications standard for sensors and actuators (Rev. A) 21 Jul 2020
    White paper PROFINET on TI’s Sitara™ processors (Rev. D) 20 Apr 2020
    Technical article How to select the right industrial Ethernet standard: EtherCAT PDF | HTML 18 Sep 2023
    Application note HSR/PRP Solutions on Sitara Processors for Grid Substation Communication 17 Apr 2018
    Application note Industrial Communication Protocols Supported on Sitara™ Processors (Rev. E) PDF | HTML 10 May 2024
    Application note Calculating Useful Lifetimes of Embedded Processors (Rev. B) PDF | HTML 10 May 2022
    White paper 為感測器選擇適合的工業通訊標準 (Rev. A) PDF | HTML 10 May 2022
    Application note Voltage and Processor Monitoring Solutions in Factory Automation and Control App (Rev. A) 10 May 2022
    Application note Programmable Logic Controllers — Security Threats and Solutions PDF | HTML 10 May 2022
    White paper Selecting the right industrial communications standard for sensors and actuators 09 May 2018
    Technical article How to select the right industrial Ethernet standard: Do you speak multiprotocol? PDF | HTML 07 Aug 2023

    Support & training

    TI E2E™ forums with technical support from TI engineers

    Content is provided "as is" by TI and community contributors and does not constitute TI specifications. See terms of use.

    If you have questions about quality, packaging or ordering TI products, see TI support.