AFE4510
- Integrated signal chains for Bio-Z, EDA, ECG, PPG
- Synchronized ECG, PPG enables PTT-based BP
- Bio-Z signal acquisition:
- Multi-frequency Body impedance Analysis with frequency programmable up to 250kHz
- Low frequency excitation mode for EDA/GSR
- Complex (I, Q). Tetrapolar impedance measurement
- Sine-wave excitation with a 7-bit DAC
- Calibration scheme to compensate for electrode impedance and achieve accurate BioZ
- ECG signal acquisition:
- 1-lead ECG signal acquisition up to 4kHz
- Mode to configure as 2-channel ECG
- INA gain programmable from 1.27 - 12.23
- RLD output to set body bias through the third electrode
- Input noise (0.5-150Hz): 0.5µVrms at gain of 12.23
- >1GΩ input impedance, CMRR>100dB
- Integrated 370 Hz anti-aliasing low pass filter
- AC, DC lead-off detect: 1.6nA to 1µA
- PPG signal acquisition:
- Acquisition of 24 PPG signal sets (LED, AMB)
- Supports PPG sensors at different data rates
- Peak system SNR of 115 dB in 0.5-10Hz band enables high-accuracy SpO2 measurement
- Low Current for Continuous Operation with a Typical Value: 19µA for the Receiver
- PPG Transmitter:
- 8-Bit Programmable LED Current with a range adjustable from 50mA to 300mA
- LED Short Detection
- Support of 16 LEDs in Common Anode configuration for SpO2, OHRM, Spectroscopy
- PPG Receiver:
- Supports 5 PDs, 4 parallel receive paths
- Noise filtering with programmable bandwidth
- Trans-impedance Gain: 3.7kΩ to 1MΩ
- 8-bit Ambient Offset Subtraction DAC up to 256µA
- 9-bit LED Offset Subtraction DAC up to 64µA
- Digital Ambient Subtraction at ADC Output
- EDA Signal Acquisition:
- Low-power continuous EDA and PPG acquisition using the ECG receiver
- Independent data rates for EDA and PPG acquisition with optimized power cycling
- High-accuracy EDA signal chain for spot-check EDA using the BIA signal chain
- Supports external clock and internal oscillator
- Option to operate 2 AFEs in parallel
- Option to configure the 5th PD input as a general purpose voltage measurement channel
- FIFO with 384-sample Depth, SPI™
- Supplies: RX,:1.7-1.9V, I/O: 1.15-1.9V, TX:3-5.5V
The AFE4510 is a versatile signal acquisition system that supports acquiring PPG, EDA, ECG, and Bio-impedance signals. A PPG signal chain comprises a current driver for LEDs and a receiver that senses the signal from PDs. An ECG receiver with a Right-leg drive (RLD) can acquire a single-lead ECG from a pair of electrodes. An impedance measurement signal chain with integrated excitation & sense can be used for applications like BIA, EDA, and Impedance spectroscopy. The outputs of the various signal chains are digitized by a common ADC and stored in a FIFO which can be read out using an SPI interface
Request more Information
Full data sheet and other design resources are available under NDA. Request now
技術文件
類型 | 標題 | 日期 | ||
---|---|---|---|---|
* | Data sheet | AFE4510 Ultra Small, Integrated AFE for Bio Impedance Analysis, Electrical Bio Sensing & Optical Bio Sensing datasheet | PDF | HTML | 2024年 3月 21日 |
設計與開發
如需其他條款或必要資源,請按一下下方的任何標題以檢視詳細頁面 (如有)。
AFE4510EVM — AFE4510 評估模組
AFE4510 支援光體積變化描記圖 (PPG)、心電圖 (ECG) 和人體阻抗分析 (BIA) 的同步訊號擷取。所有 3 種訊號鏈的 ADC 輸出皆儲存在 384 取樣的先進先出 (FIFO) 區塊中,可利用 SPI 讀取。晶片具有共用相同 ADC 的 PPG、ECG 和 Bio-Z 的獨立訊號鏈。可定義獨立訊號擷取窗口來擷取 PPG、ECG 和/或 Bio-Z 訊號。每個訊的採集速率皆可獨立設定。支援最多 24 個 PPG 訊號 (包含最多 16 個 LED 和最多 5 個 PD) 同步擷取,進而實現光學心率監測 (OHRM) 和血氧濃度分析等應用。AFE 支援多訊號擷取模式,其中包括純 (...)
PSPICE-FOR-TI — PSpice® for TI 設計與模擬工具
封裝 | 針腳 | CAD 符號、佔位空間與 3D 模型 |
---|---|---|
DSBGA (YBG) | 42 | Ultra Librarian |
訂購與品質
- RoHS
- REACH
- 產品標記
- 鉛塗層/球物料
- MSL 等級/回焊峰值
- MTBF/FIT 估算值
- 材料內容
- 認證摘要
- 進行中持續性的可靠性監測
- 晶圓廠位置
- 組裝地點
建議產品可能具有與此 TI 產品相關的參數、評估模組或參考設計。