Guidelines for routing PCB traces and placing components are necessary when trying to maintain signal integrity, avoiding noise pick-up, and lower EMI. Although an endless number of precautions seems to be taken, this section provides only a few main recommendations as layout guidance.
- Keep signal traces 3 times the trace-to-ground height, (d = 3h), apart to reduce crosstalk down to 10%. Because the return current density under a signal trace diminishes via a 1/ [1+(d/h)2] function, its density at a point d > 3h, is sufficiently small to avoid causing significant crosstalk in an adjacent trace.
- Use 45° bends (chamfered corners), instead of right-angle (90°) bends. Right-angle bends increase the effective trace width, and thus the trace impedance. This creates additional impedance mismatch, which may lead to higher reflections.
- For permanent operation in noisy environments, connect the Enable inputs of an isolator through a via to the appropriate reference plane, that is, High-Enable inputs to the VCC plane and Low-Enable inputs to the ground plane.
- When routing traces next to a via or between an array of vias, ensure that the via clearance section does not interrupt the path of the return current on the ground plane below. If a via clearance section lies in the return path, the return current finds a path of least inductance around it. By doing so, it may cross below other signal traces, thus generating cross-talk and increase EMI.
- Avoid changing layers with signal traces as this causes the inductance of the signal path to increase.
- If, however, signal trace routing over different layers is unavoidable, accompany each signal trace via with a return-trace via. In this case, use the smallest via size possible to keep the increase in inductance at a minimum.
- Use solid power and ground planes for impedance control and minimum power noise.
- Use short trace lengths between isolator and surrounding circuits to avoid noise pick-up. Digital isolators are usually accompanied by isolated dc-to-dc converters, providing supply power across the isolation barrier. Because single-ended transmission signaling is sensitive to noise pick-up, the switching frequencies of close-by dc-to-dc converters can be easily picked up by long signal traces.
- Place bulk capacitors, (i.e., 10 μF), close to power sources, such as voltage regulators or where the power is supplied to the PCB.
- Place smaller 0.1-μF or 0.01-μF bypass capacitors at the device by connecting the power-side of the capacitor directly to the supply terminal of the device and through two vias to the Vcc plane, and the ground-side of the capacitor through two vias to the ground plane.