SLVUBG5A June 2018 – September 2021 ESD122 , ESD204 , ESD401 , SN65220 , SN65240 , TPD1E01B04 , TPD1E04U04 , TPD1E05U06 , TPD1E10B06 , TPD1E10B06-Q1 , TPD1E10B09 , TPD1E10B09-Q1 , TPD2E001 , TPD2E001-Q1 , TPD2E009 , TPD2E1B06 , TPD2E2U06-Q1 , TPD2EUSB30 , TPD2S017 , TPD4E001-Q1 , TPD4E004 , TPD4E02B04 , TPD4E05U06 , TPD4E05U06-Q1 , TPD4E101 , TPD4E1B06 , TPD4E1U06 , TPD4E6B06 , TPD5E003 , TPD6E001 , TPD6E004 , TPD6E05U06 , TPD8E003 , TPD8S009 , TVS2200 , UC1611-SP , UC2610 , UC3610 , UC3611 , UC3611M
IEC61000-4-2 has 4 classes of protection levels. Classes 1 – 4 are shown in Table 2-1. Stress tests should be incrementally tested to level 4 as shown in Table 2-2 until the point of failure. If the DUT does not fail at 8 kV, testing can continue in 2 kV increments until failure.
Contact Discharge | Air Discharge | ||
---|---|---|---|
Class | Test Voltage [± kV] | Class | Test Voltage [± kV] |
1 | 2 | 1 | 2 |
2 | 4 | 2 | 4 |
3 | 6 | 3 | 8 |
4 | 8 | 4 | 15 |
Stress Level Step | Simulator Voltage [kV] | Ipeak ±15% [A] | Rise Time ±25% [nS] | Current at 30ns ±30% [A] | Current at 60ns ±30% [A] |
---|---|---|---|---|---|
1 | 2 | 7.5 | 0.8 | 4 | 2 |
2 | 4 | 15 | 0.8 | 8 | 4 |
3 | 6 | 22.5 | 0.8 | 12 | 6 |
4 | 8 | 30 | 0.8 | 16 | 8 |