SPRADE3 January   2024 ADS8329 , LM5110 , LM5111 , LM5180 , LMR38010 , OPA182 , SM72482 , SN75372 , TMS320F28384D , TPS2811 , TPS2813 , UC1707-SP , UC1708 , UC1708-SP , UC1709-SP , UC1715-SP , UC2714 , UC3708 , UC3709 , UCC27323 , UCC27324 , UCC27324-Q1 , UCC27325 , UCC27423 , UCC27423-EP , UCC27423-Q1 , UCC27424 , UCC27424-EP , UCC27424-Q1 , UCC27425 , UCC27425-Q1 , UCC27444 , UCC27444-Q1 , UCC27523 , UCC27524 , UCC27524A , UCC27524A-Q1 , UCC27524A1-Q1 , UCC27525 , UCC27526 , UCC27527 , UCC27528 , UCC27528-Q1 , UCC27624 , UCC27624-Q1 , UCC37323 , UCC37324 , UCC37325 , UCD7201

 

  1.   1
  2.   Abstract
  3.   Trademarks
  4. 1Introduction
    1. 1.1 Magnet of the MRI
    2. 1.2 Key Challenge to Design a Power Supply to Driver Superconductor
  5. 2Four-Phase Interleaving Phase-Shifted Full Bridge Power Supply Design
  6. 3Sub-System Description
    1. 3.1 Micro-Controller
    2. 3.2 Auxiliary Power Supply
    3. 3.3 Current Sensing
    4. 3.4 ADC Interface
    5. 3.5 MOSFET Driver
  7. 4Summary
  8. 5References

References

  1. Journal of Instrumentation, The design and development of DAB DC- DC converter for HF MRI superconducting magnet power supply T. Dai, F. Wang, S. Xue, P. Gao, Z. Zhang, J. Qin, C. Zhou and J. Li.
  2. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, The design of power supply for HF MRI superconducting magnet,Tianli Dai, Chao Zhou, Jinggang Qin, Lican He, Jiangang Li
  3. International Symposium on Power Electronics, High-current low-voltage power supplies for superconducting magnets, E. Coulinge, J. -P. Burnet and D. Dujic,
  4. Peking University Press,Magnetic Resonance Imaging Equipment and Technology 2Hongbin Han016,
  5. China Science Publishing Press, Magnetic Resonance imaging: Principles, structures and design, Donglin Zu.