Produktdetails

Number of series cells 1 Charge current (max) (A) 6 Vin (max) (V) 12 Cell chemistry Li-Ion/Li-Polymer, Lithium Phosphate/LiFePO4 Battery charge voltage (min) (V) 3.5 Battery charge voltage (max) (V) 4.65 Absolute max Vin (max) (V) 20 Control topology Flash Charger Control interface I2C Features BAT temp thermistor monitoring (hot/cold profile), IC thermal regulation, Input OVP, Integrated ADC Vin (min) (V) 3.2 Rating Catalog Operating temperature range (°C) -40 to 85
Number of series cells 1 Charge current (max) (A) 6 Vin (max) (V) 12 Cell chemistry Li-Ion/Li-Polymer, Lithium Phosphate/LiFePO4 Battery charge voltage (min) (V) 3.5 Battery charge voltage (max) (V) 4.65 Absolute max Vin (max) (V) 20 Control topology Flash Charger Control interface I2C Features BAT temp thermistor monitoring (hot/cold profile), IC thermal regulation, Input OVP, Integrated ADC Vin (min) (V) 3.2 Rating Catalog Operating temperature range (°C) -40 to 85
DSBGA (YFF) 56 10.7999999999999988 mm² 3 x 3.5999999999999996
  • 97% Efficient power stage for 6-A fast charge
  • Patent pending switched cap charger architecture optimized for 50% duty cycle
    • Input voltage is 2x battery voltage (3.5 V to 4.65 V)
    • Output current is 2x of input current (up to 4.5 A)
    • Reduces power loss across the cable
  • Integrated programmable protection features for safe operation
    • Input overvoltage protection (BUS_OVP)
    • Input overcurrent protection (BUS_OCP) with adjustable alarm
    • Input overvoltage with external OVP FET (VAC_OVP up to 17 V)
    • Battery overvoltage protection (BAT_OVP) with adjustable alarm
    • Output overvoltage (VOUT_OVP)
    • Input overcurrent protection (BUS_OCP) with adjustable alarm
    • IBAT overcurrent protection (BAT_OCP) with adjustable alarm
    • Switching MOSFET cycle-by-cycle current limit
    • Battery temperature monitoring
    • Connector temperature monitoring
  • Programmable settings for system optimization
    • STAT, FLAG, and MASK options for interrupts
    • ADC readings and configuration
  • Integrated 16-bit effective analog-to digital converter (ADC)
    • ±0.5% BUS voltage
    • ±0.5% VOUT voltage
    • –0.4% to 0.2% BAT voltage with differential sensing
    • ±1.5% BAT current at 6 A with external RSENSE
    • ±1% BAT temperature
    • ±1% BUS temperature
    • ±4°C die temperature
  • 97% Efficient power stage for 6-A fast charge
  • Patent pending switched cap charger architecture optimized for 50% duty cycle
    • Input voltage is 2x battery voltage (3.5 V to 4.65 V)
    • Output current is 2x of input current (up to 4.5 A)
    • Reduces power loss across the cable
  • Integrated programmable protection features for safe operation
    • Input overvoltage protection (BUS_OVP)
    • Input overcurrent protection (BUS_OCP) with adjustable alarm
    • Input overvoltage with external OVP FET (VAC_OVP up to 17 V)
    • Battery overvoltage protection (BAT_OVP) with adjustable alarm
    • Output overvoltage (VOUT_OVP)
    • Input overcurrent protection (BUS_OCP) with adjustable alarm
    • IBAT overcurrent protection (BAT_OCP) with adjustable alarm
    • Switching MOSFET cycle-by-cycle current limit
    • Battery temperature monitoring
    • Connector temperature monitoring
  • Programmable settings for system optimization
    • STAT, FLAG, and MASK options for interrupts
    • ADC readings and configuration
  • Integrated 16-bit effective analog-to digital converter (ADC)
    • ±0.5% BUS voltage
    • ±0.5% VOUT voltage
    • –0.4% to 0.2% BAT voltage with differential sensing
    • ±1.5% BAT current at 6 A with external RSENSE
    • ±1% BAT temperature
    • ±1% BUS temperature
    • ±4°C die temperature

The BQ25968 is a 97% efficient, 6-A battery charging solution using a switched cap architecture. This architecture and the integrated FETs are optimized to enable a 50% duty cycle, allowing the cable current to be half the current delivered to the battery, reducing the losses over the charging cable as well as limiting the temperature rise in the application.

The dual-phase architecture increases charging efficiency and reduces the input and ouput cap requirements. When used with a main charger such as BQ25790, the system enables the fastest charging at the lowest power loss from precharge through CC, CV, and termination.

The dual-phase architecture reduces the input cap requirements as well as reducing the output voltage ripple. When used with a standard charger such as the BQ2589x, the system enables the fastest charging at the lowest power loss from precharge through CC, CV, and termination.

The device integrates all the necessary protection features to ensure safe charging, including input over-voltage and over-current protection, output overvoltage and overcurrent protection, temperature sensing for the battery and cable, and monitoring the die temperature.

The device includes a 12-bit effective analog-to-digital converter (ADC) to provide bus voltage, bus current, output voltage, battery voltage, battery current, bus temperature, bat temperature, die temperature, and other calculated measurements needed to manage the charging of the battery from the smart wall adapter or power bank.

The BQ25968 is a 97% efficient, 6-A battery charging solution using a switched cap architecture. This architecture and the integrated FETs are optimized to enable a 50% duty cycle, allowing the cable current to be half the current delivered to the battery, reducing the losses over the charging cable as well as limiting the temperature rise in the application.

The dual-phase architecture increases charging efficiency and reduces the input and ouput cap requirements. When used with a main charger such as BQ25790, the system enables the fastest charging at the lowest power loss from precharge through CC, CV, and termination.

The dual-phase architecture reduces the input cap requirements as well as reducing the output voltage ripple. When used with a standard charger such as the BQ2589x, the system enables the fastest charging at the lowest power loss from precharge through CC, CV, and termination.

The device integrates all the necessary protection features to ensure safe charging, including input over-voltage and over-current protection, output overvoltage and overcurrent protection, temperature sensing for the battery and cable, and monitoring the die temperature.

The device includes a 12-bit effective analog-to-digital converter (ADC) to provide bus voltage, bus current, output voltage, battery voltage, battery current, bus temperature, bat temperature, die temperature, and other calculated measurements needed to manage the charging of the battery from the smart wall adapter or power bank.

Herunterladen Video mit Transkript ansehen Video

Technische Dokumentation

star =Von TI ausgewählte Top-Empfehlungen für dieses Produkt
Keine Ergebnisse gefunden. Bitte geben Sie einen anderen Begriff ein und versuchen Sie es erneut.
Alle anzeigen 1
Typ Titel Datum
* Data sheet BQ25968 I2C Controlled Single Cell High Efficiency 6-A Switched Cap Fast Charger With ADC datasheet (Rev. A) PDF | HTML 19 Feb 2021

Design und Entwicklung

Weitere Bedingungen oder erforderliche Ressourcen enthält gegebenenfalls die Detailseite, die Sie durch Klicken auf einen der unten stehenden Titel erreichen.

Gehäuse Pins CAD-Symbole, Footprints und 3D-Modelle
DSBGA (YFF) 56 Ultra Librarian

Bestellen & Qualität

Beinhaltete Information:
  • RoHS
  • REACH
  • Bausteinkennzeichnung
  • Blei-Finish/Ball-Material
  • MSL-Rating / Spitzenrückfluss
  • MTBF-/FIT-Schätzungen
  • Materialinhalt
  • Qualifikationszusammenfassung
  • Kontinuierliches Zuverlässigkeitsmonitoring
Beinhaltete Information:
  • Werksstandort
  • Montagestandort

Support und Schulungen

TI E2E™-Foren mit technischem Support von TI-Ingenieuren

Inhalte werden ohne Gewähr von TI und der Community bereitgestellt. Sie stellen keine Spezifikationen von TI dar. Siehe Nutzungsbedingungen.

Bei Fragen zu den Themen Qualität, Gehäuse oder Bestellung von TI-Produkten siehe TI-Support. ​​​​​​​​​​​​​​

Videos