AFE4420
- Supports signal acquisition of up to 16 phases
- Flexible allocation of LEDs and PDs in each phase
- Accurate, continuous heart-rate monitoring:
- Up to 100-dB dynamic range
- Low current for continuous operation on a wearable device with a typical value
- 15 µA for an LED, 20 µA for the receiver
- Transmitter:
- Supports common anode LED configuration
- 8-Bit programmable LED current with range adjustable from 50 mA to 200 mA
- Mode to fire two LEDs in parallel
- Programmable LED on-time
- Simultaneous support of 4 LEDs for optimized SpO2, HRM, or multi-wavelength HRM
- Programmable control signals to extend operation to 8 LEDs using external SPDT switches
- Receiver:
- Supports 4 time-multiplexed photodiode inputs
- Individual DC offset subtraction DAC at TIA input for each LED, ambient with 7-bit control and range up to ±254 µA
- Transimpedance gain: 10 kΩ to 2 MΩ
- Digital ambient subtraction at ADC output to suppress ambient tones
- Noise filtering with programmable bandwidth
- Supports external clock and internal oscillator modes
- Automatic ambient cancellation mode (AACM) to increase receiver dynamic range
- Two programmable GPIO pins with flexible interrupt generation
- FIFO with 128-sample depth
- I2C, SPI interfaces: selectable by pin
- Operating temperature range: –40°C to +85°C
- 2.6-mm × 2.1-mm DSBGA, 0.4-mm pitch
- Supplies:
- Rx:
- 1.7 V to 1.9 V (LDO bypass)
- 1.9 V to 3.6 V (LDO enabled)
- Tx: 3 V to 5.5 V
- IO: 1.7 V to RX_SUP
- Rx:
The AFE4420 is an analog front-end for optical bio-sensing applications, such as heart-rate monitoring (HRM) and saturation of peripheral capillary oxygen (SpO2). The device supports up to four switching light-emitting diodes (LEDs) and up to four photodiodes. Up to 16 signal phases can be defined and the signal can be acquired from each phase in a synchronized manner and stored in a 128-sample First in, First out (FIFO) block. The FIFO can be read out using either an I2C or a SPI interface. The AFE also has a fully integrated LED driver with an 8-bit current control. The device has a high dynamic range transmit-and-receive circuitry that helps with the sensing of very small signal levels.
詳細資訊
在 NDA 下提供完整產品規格表和其它設計資源。立即索取
您可能會感興趣的類似產品
技術文件
類型 | 標題 | 日期 | ||
---|---|---|---|---|
* | Data sheet | AFE4420 Ultra-Small, Integrated AFE With FIFO for Multi-sensor Wearable, Optical Heart-rate Monitoring and Bio-sensing datasheet (Rev. A) | PDF | HTML | 2019年 7月 30日 |
Technical article | Designing compact, efficient and high performing multiparameter patient monitors | PDF | HTML | 2019年 6月 25日 | |
Technical article | Going beyond traditional SpO2 measurement with multiwavelength optical measurement | PDF | HTML | 2019年 2月 12日 |
設計與開發
如需其他條款或必要資源,請按一下下方的任何標題以檢視詳細頁面 (如有)。
AFE4420EVM — 具有 FIFO 且適用於穿戴式光學心率監控的 AFE4420 整合式 AFE 評估模組
AFE4420 評估模組 (EVM) 是評估 AFE4420 裝置的平台,其為光學生物感測應用領域的類比前端 (AFE),如心率監控 (HRM) 與周邊微血管氧飽和度 (SpO2)。AFE4420 支援八個切換發光二極體 (LED) 以及四個光二極體。光二極體電流透過轉阻放大器 (TIA) 轉換為電壓,並使用類比轉數位轉換器 (ADC) 進行數位化。ADC 程式碼可以儲存在具有可編程深度的 128 取樣 FIFO 中。可以對 FIFO 深度進行分區以適應需要儲存的相位。FIFO 可使用 I2C 介面或序列周邊介面 (SPI) 讀出。
AFE4420 也配備具 8 (...)
PSPICE-FOR-TI — PSpice® for TI 設計與模擬工具
TIDA-010029 — 具備 Bluetooth® 5 的穿戴式 16 相位多感測器 SpO2 與心率監測器 (HRM) 參考設計
封裝 | 針腳 | CAD 符號、佔位空間與 3D 模型 |
---|---|---|
DSBGA (YZ) | 30 | Ultra Librarian |
訂購與品質
- RoHS
- REACH
- 產品標記
- 鉛塗層/球物料
- MSL 等級/回焊峰值
- MTBF/FIT 估算值
- 材料內容
- 認證摘要
- 進行中持續性的可靠性監測
- 晶圓廠位置
- 組裝地點
建議產品可能具有與此 TI 產品相關的參數、評估模組或參考設計。