SBAA274A September 2018 – March 2023 ADS1118 , ADS1119 , ADS1120 , ADS112C04 , ADS112U04 , ADS1146 , ADS1147 , ADS1148 , ADS114S06 , ADS114S06B , ADS114S08 , ADS114S08B , ADS1219 , ADS1220 , ADS122C04 , ADS122U04 , ADS1246 , ADS1247 , ADS1248 , ADS124S06 , ADS124S08 , ADS125H02 , ADS1260 , ADS1261 , ADS1262 , ADS1263
In the previous thermocouple circuits, cold-junction compensation was not discussed. The following sections show several examples of cold-junction temperature measurements using other input channels for the ADC. Several different temperature sensors are shown in different circuit topologies.
Regardless of the temperature sensor being used, ensure that the cold-junction measurement accurately measures the temperature of the isothermal block connecting the leads of the thermocouple.