AFE49I30

AKTIV

Integriertes AFE mit extrem geringem Stromverbrauch für optische Wearable-Biosensorik mit FIFO, I2C

Produktdetails

Applications 1-lead ECG, Optical-HRM Number of input channels 4 Resolution (Bits) 22 Number of LEDs 6 Interface type I2C Operating temperature range (°C) -40 to 85 Rating Catalog
Applications 1-lead ECG, Optical-HRM Number of input channels 4 Resolution (Bits) 22 Number of LEDs 6 Interface type I2C Operating temperature range (°C) -40 to 85 Rating Catalog
DSBGA (YZ) 30 4.8 mm² 2.4 x 2
  • Supports signal acquisition of up to 24 phases
  • Flexible allocation of 6 LED, 4 PD in each PPG phase
  • Synchronized PPG/ECG signal acquisition with each phase configurable as PPG or ECG, and at different data rates
  • Synchronized PPG/ECG supports up to 1 kHz data rate
  • ECG-only mode supports up to 4 kHz data rate
  • PPG signal chain:
    • System SNR up to 108-dB at 16 µA PD current
    • Low current for continuous operation on a wearable device with a typical value: 15 µA for an LED, 20 µA for the receiver
  • PPG Transmitter:
    • Supports common anode LED configuration
    • 8-Bit programmable LED current with range adjustable from 25 mA to 250 mA
    • Mode to fire two LEDs in parallel with independent per-phase current control
    • Programmable LED on-time per-phase
    • Simultaneous support of 6 LEDs for SpO2, HRM, or multi-wavelength HRM
  • PPG Receiver:
    • Supports 4 time-multiplexed photodiode inputs
    • 2 parallel receivers to sample two PD channels simultaneously
    • Individual ambient offset subtraction DAC at each TIA Input with 8-bit per-phase control and range adjustable up to 255-µA
    • Individual LED offset subtraction DAC at each TIA input with 5-bit per-phase control and
      15.5-µA range
    • Close to 100 dB ambient rejection up to 10 Hz
    • Noise filtering with programmable bandwidth
    • Transimpedance Gain: 3.7 kΩ to 1 MΩ
  • ECG Signal Chain
    • 1-lead ECG with RLD output for bias
    • INA gain programmable from 1.6 – 13
    • <1 µVrms input noise (in a 1-150 Hz bandwidth) at 4-kHz sample rate
    • Integrated 450 Hz Low Pass Filter
    • AC, DC lead-off detect with 3.125-100 nA current and programmable interrupt
  • Supports external clock and internal oscillator modes
  • Option to acquire data synchronized with a system master clock
  • Automatic cancellation of DC from ambient, LED
  • FIFO with 128-sample depth
  • I2C interface
  • 2.6-mm × 2.1-mm DSBGA, 0.4-mm pitch
  • Supplies: Rx: 1.7 V-1.9 V (LDO bypass); 1.9 V-3.6 V (LDO enabled), Tx: 3 V-5.5 V, IO: 1.7-3.6 V
  • Supports operation with 2 supplies - 1.8 V, 5 V
  • Supports signal acquisition of up to 24 phases
  • Flexible allocation of 6 LED, 4 PD in each PPG phase
  • Synchronized PPG/ECG signal acquisition with each phase configurable as PPG or ECG, and at different data rates
  • Synchronized PPG/ECG supports up to 1 kHz data rate
  • ECG-only mode supports up to 4 kHz data rate
  • PPG signal chain:
    • System SNR up to 108-dB at 16 µA PD current
    • Low current for continuous operation on a wearable device with a typical value: 15 µA for an LED, 20 µA for the receiver
  • PPG Transmitter:
    • Supports common anode LED configuration
    • 8-Bit programmable LED current with range adjustable from 25 mA to 250 mA
    • Mode to fire two LEDs in parallel with independent per-phase current control
    • Programmable LED on-time per-phase
    • Simultaneous support of 6 LEDs for SpO2, HRM, or multi-wavelength HRM
  • PPG Receiver:
    • Supports 4 time-multiplexed photodiode inputs
    • 2 parallel receivers to sample two PD channels simultaneously
    • Individual ambient offset subtraction DAC at each TIA Input with 8-bit per-phase control and range adjustable up to 255-µA
    • Individual LED offset subtraction DAC at each TIA input with 5-bit per-phase control and
      15.5-µA range
    • Close to 100 dB ambient rejection up to 10 Hz
    • Noise filtering with programmable bandwidth
    • Transimpedance Gain: 3.7 kΩ to 1 MΩ
  • ECG Signal Chain
    • 1-lead ECG with RLD output for bias
    • INA gain programmable from 1.6 – 13
    • <1 µVrms input noise (in a 1-150 Hz bandwidth) at 4-kHz sample rate
    • Integrated 450 Hz Low Pass Filter
    • AC, DC lead-off detect with 3.125-100 nA current and programmable interrupt
  • Supports external clock and internal oscillator modes
  • Option to acquire data synchronized with a system master clock
  • Automatic cancellation of DC from ambient, LED
  • FIFO with 128-sample depth
  • I2C interface
  • 2.6-mm × 2.1-mm DSBGA, 0.4-mm pitch
  • Supplies: Rx: 1.7 V-1.9 V (LDO bypass); 1.9 V-3.6 V (LDO enabled), Tx: 3 V-5.5 V, IO: 1.7-3.6 V
  • Supports operation with 2 supplies - 1.8 V, 5 V

The AFE49I30 is an analog front-end for optical bio-sensing/ PPG and ECG measurement applications. The device supports up to six switching light-emitting diodes (LEDs) and up to four photodiodes. Up to 24 signal phases can be defined and the PPG or ECG signals can be acquired from each phase in a synchronized manner.

The AFE49I30 is an analog front-end for optical bio-sensing/ PPG and ECG measurement applications. The device supports up to six switching light-emitting diodes (LEDs) and up to four photodiodes. Up to 24 signal phases can be defined and the PPG or ECG signals can be acquired from each phase in a synchronized manner.

Herunterladen Video mit Transkript ansehen Video

Weitere Informationen anfordern

Das vollständige Datenblatt und weitere Designressourcen sind unter NDA verfügbar. Jetzt anfordern

Ähnliche Produkte, die für Sie interessant sein könnten

Selbe Funktionalität wie der verglichene Baustein bei abweichender Anschlussbelegung
AFE4950 AKTIV Extrem kleines integriertes AFE für tragbare optische Herzfrequenzüberwachung und SpO2 ECG+PPG AFE with integrated high-pass, low-pass filters optimized for dry electrodes.

Technische Dokumentation

star =Von TI ausgewählte Top-Empfehlungen für dieses Produkt
Keine Ergebnisse gefunden. Bitte geben Sie einen anderen Begriff ein und versuchen Sie es erneut.
Alle anzeigen 1
Typ Titel Datum
* Data sheet AFE49I30 Ultra-Small, Integrated AFE With FIFO for Multi-Sensor Wearable, Optical Heart-Rate Monitoring and Bio-sensing datasheet PDF | HTML 13 Apr 2020

Design und Entwicklung

Weitere Bedingungen oder erforderliche Ressourcen enthält gegebenenfalls die Detailseite, die Sie durch Klicken auf einen der unten stehenden Titel erreichen.

Evaluierungsplatine

AFE44S30EVM — AFE4430 Integriertes AFE mit extrem geringem Stromverbrauch für optische Wearable-Biosensorik mit FI

Das AFE44S30 Evaluierungsmodul (EVM) ist eine Plattform zur Evaluierung des AFE44S30 Bausteins, eines analogen Front-Ends (AFE) für optische Biosensor-Anwendungen, wie z.B. die Überwachung der Herzfrequenz (HRM) und die Sättigung des peripheren Kapillarsauerstoffs (SpO2). AFE44S30 (...)

Evaluierungsplatine

AFE49I30EVM — AFE49I30 Integriertes AFE für optische Wearable-Biosensorik – Evaluierungsmodul

Das AFE4500-Evaluierungsmodul (EVM) wurde entwickelt, um die Evaluierungs- und Systementwicklungsaktivitäten im Zusammenhang mit dem AFE49I30 zu beschleunigen. AFE49I30 ist ein analoges Frontend (AFE) für optische Biosensoranwendungen wie die Herzfrequenzüberwachung (HRM) und die Sättigung des (...)

Treiber oder Bibliothek

BSECUR-3P-ALGORITHMS — B SECUR ECG Algorithms and Electrode Design Services

HeartKey is a powerful and accurate set of ECG algorithms, ready for integration into the next generation low power low memory consumer / IoT & medical devices such as smartwatches, smart clothing, medical, automotive, smart home devices and hand-held devices. HeartKey is comprised of advanced (...)
Von: B Secur
Simulationstool

PSPICE-FOR-TI — PSpice® für TI Design-und Simulationstool

PSpice® für TI ist eine Design- und Simulationsumgebung, welche Sie dabei unterstützt, die Funktionalität analoger Schaltungen zu evaluieren. Diese voll ausgestattete Design- und Simulationssuite verwendet eine analoge Analyse-Engine von Cadence®. PSpice für TI ist kostenlos erhältlich und (...)
Gehäuse Pins CAD-Symbole, Footprints und 3D-Modelle
DSBGA (YZ) 30 Ultra Librarian

Bestellen & Qualität

Beinhaltete Information:
  • RoHS
  • REACH
  • Bausteinkennzeichnung
  • Blei-Finish/Ball-Material
  • MSL-Rating / Spitzenrückfluss
  • MTBF-/FIT-Schätzungen
  • Materialinhalt
  • Qualifikationszusammenfassung
  • Kontinuierliches Zuverlässigkeitsmonitoring
Beinhaltete Information:
  • Werksstandort
  • Montagestandort

Empfohlene Produkte können Parameter, Evaluierungsmodule oder Referenzdesigns zu diesem TI-Produkt beinhalten.

Support und Schulungen

TI E2E™-Foren mit technischem Support von TI-Ingenieuren

Inhalte werden ohne Gewähr von TI und der Community bereitgestellt. Sie stellen keine Spezifikationen von TI dar. Siehe Nutzungsbedingungen.

Bei Fragen zu den Themen Qualität, Gehäuse oder Bestellung von TI-Produkten siehe TI-Support. ​​​​​​​​​​​​​​

Videos