The bq24298 is a highly-integrated switch-mode battery charge management and system power
path management device for 1 cell Li-Ion and Li-polymer battery in a wide range of smart phone and
tablet applications. Its low impedance power path optimizes switch-mode operation efficiency,
reduces battery charging time and extends battery life during discharging phase.
The I2C serial interface with charging and system settings
makes the device a truly flexible solution.
The device supports 3.9V – 6.2V USB input sources, including standard USB host port and
USB charging port with 6.4V over-voltage protection. The device supports USB 2.0 and USB 3.0 power
specifications with input current and voltage regulation. To set the default input current limit,
the bq24298 takes the result from the detection circuit in the system, such as USB PHY device. The
device also supports USB On-the-Go operation by providing fast startup and supplying adjustable
voltage 4.55 – 5.5V (default 5V) on the VBUS with an accurate current limit up to 1.5A.
The power path management regulates the system slightly above battery voltage but does
not drop below 3.5V minimum system voltage (programmable). With this feature, the system keeps
operating even when the battery is completely depleted or removed. When the input source current or
voltage limit is reached, the power path management automatically reduces the charge current to
zero and then starts discharges the battery until the system power requirement is met. This
supplement mode operation keeps the input source from getting overloaded.
The device initiates and completes a charging cycle when host control is not available.
It automatically charges the battery in three phases: pre-conditioning, constant current and
constant voltage. In the end, the charger automatically terminates when the charge current is below
a preset limit in the constant voltage phase. Later on, when the battery voltage falls below the
recharge threshold, the charger will automatically start another charging cycle.
The charge device provides various safety features for battery charging and system
operation, including negative thermistor monitoring, charging safety timer and
over-voltage/over-current protections. The thermal regulation reduces charge current when the
junction temperature exceeds 120°C (programmable).
The STAT output reports the charging status and any fault conditions. The INT immediately
notifies host when fault occurs.
The bq24298 is available in a 24-pin, 4.00-mm × 4.00-mm thin WQFN package.
The bq24298 is a highly-integrated switch-mode battery charge management and system power
path management device for 1 cell Li-Ion and Li-polymer battery in a wide range of smart phone and
tablet applications. Its low impedance power path optimizes switch-mode operation efficiency,
reduces battery charging time and extends battery life during discharging phase.
The I2C serial interface with charging and system settings
makes the device a truly flexible solution.
The device supports 3.9V – 6.2V USB input sources, including standard USB host port and
USB charging port with 6.4V over-voltage protection. The device supports USB 2.0 and USB 3.0 power
specifications with input current and voltage regulation. To set the default input current limit,
the bq24298 takes the result from the detection circuit in the system, such as USB PHY device. The
device also supports USB On-the-Go operation by providing fast startup and supplying adjustable
voltage 4.55 – 5.5V (default 5V) on the VBUS with an accurate current limit up to 1.5A.
The power path management regulates the system slightly above battery voltage but does
not drop below 3.5V minimum system voltage (programmable). With this feature, the system keeps
operating even when the battery is completely depleted or removed. When the input source current or
voltage limit is reached, the power path management automatically reduces the charge current to
zero and then starts discharges the battery until the system power requirement is met. This
supplement mode operation keeps the input source from getting overloaded.
The device initiates and completes a charging cycle when host control is not available.
It automatically charges the battery in three phases: pre-conditioning, constant current and
constant voltage. In the end, the charger automatically terminates when the charge current is below
a preset limit in the constant voltage phase. Later on, when the battery voltage falls below the
recharge threshold, the charger will automatically start another charging cycle.
The charge device provides various safety features for battery charging and system
operation, including negative thermistor monitoring, charging safety timer and
over-voltage/over-current protections. The thermal regulation reduces charge current when the
junction temperature exceeds 120°C (programmable).
The STAT output reports the charging status and any fault conditions. The INT immediately
notifies host when fault occurs.
The bq24298 is available in a 24-pin, 4.00-mm × 4.00-mm thin WQFN package.