PGA308

AKTIV

Verstärker mit Autozero-Sensor; einzelne Stromversorgung, Verstärkung und Offset programmierbar

Produktdetails

PGA/VGA PGA Number of channels 2 Vs (max) (V) 5.5 Vs (min) (V) 2.7 Slew rate (typ) (V/µs) 0.6 Rating Catalog Operating temperature range (°C) -40 to 125
PGA/VGA PGA Number of channels 2 Vs (max) (V) 5.5 Vs (min) (V) 2.7 Slew rate (typ) (V/µs) 0.6 Rating Catalog Operating temperature range (°C) -40 to 125
VSON (DRK) 10 12 mm² 4 x 3 VSSOP (DGS) 10 14.7 mm² 3 x 4.9
  • Digital Calibration for Bridge Sensors
  • Offset Select: Coarse and Fine
  • Gain Select: Coarse and Fine
  • Bridge Fault Monitor
  • Input Mux for Lead Swap
  • Over/Under Scale Limits
  • DOUT/VOUT Clamp Function
  • Seven Banks OTP Memory
  • One-Wire Digital UART Interface
  • Operating Voltage: +2.7V to +5.5V
  • Temperature Range: –40°C to +125°C
  • MSOP-10 and 3mm × 4mm DFN-10 Packages
  • Digital Calibration for Bridge Sensors
  • Offset Select: Coarse and Fine
  • Gain Select: Coarse and Fine
  • Bridge Fault Monitor
  • Input Mux for Lead Swap
  • Over/Under Scale Limits
  • DOUT/VOUT Clamp Function
  • Seven Banks OTP Memory
  • One-Wire Digital UART Interface
  • Operating Voltage: +2.7V to +5.5V
  • Temperature Range: –40°C to +125°C
  • MSOP-10 and 3mm × 4mm DFN-10 Packages

The PGA308 is a programmable analog sensor signal conditioner. The analog signal path amplifies the sensor signal and provides digital calibration for offset and gain. Calibration is done via the 1W pin, a digital One-Wire, UART-compatible interface. For three-terminal sensor modules, 1W may be connected to VOUT and the assembly programmed through the VOUT pin. Gain and offset calibration parameters are stored onboard in seven banks of one-time programmable (OTP) memory. The power-on reset (POR) OTP bank may be programmed a total of four times.

The all-analog signal path contains a 2×2 input multiplexer (mux) to allow electronic sensor lead swapping, a coarse offset adjust, an auto-zero programmable gain instrumentation amplifier (PGA), a fine gain adjust, a fine offset adjust, and a programmable gain output amplifier. Fault monitor circuitry detects and signals sensor burnout, overload, and system fault conditions. Over/under-scale limits provide additional means for system level diagnostics. The dual-use DOUT/VCLAMP pin can be used as a programmable digital output or as a VOUT over-voltage clamp.

For detailed application information, see the PGA308 User's Guide (SBOU069) available for download at www.ti.com.

The PGA308 is a programmable analog sensor signal conditioner. The analog signal path amplifies the sensor signal and provides digital calibration for offset and gain. Calibration is done via the 1W pin, a digital One-Wire, UART-compatible interface. For three-terminal sensor modules, 1W may be connected to VOUT and the assembly programmed through the VOUT pin. Gain and offset calibration parameters are stored onboard in seven banks of one-time programmable (OTP) memory. The power-on reset (POR) OTP bank may be programmed a total of four times.

The all-analog signal path contains a 2×2 input multiplexer (mux) to allow electronic sensor lead swapping, a coarse offset adjust, an auto-zero programmable gain instrumentation amplifier (PGA), a fine gain adjust, a fine offset adjust, and a programmable gain output amplifier. Fault monitor circuitry detects and signals sensor burnout, overload, and system fault conditions. Over/under-scale limits provide additional means for system level diagnostics. The dual-use DOUT/VCLAMP pin can be used as a programmable digital output or as a VOUT over-voltage clamp.

For detailed application information, see the PGA308 User's Guide (SBOU069) available for download at www.ti.com.

Herunterladen Video mit Transkript ansehen Video

Ähnliche Produkte, die für Sie interessant sein könnten

Gleiche Funktionalität, andere Pinbelegung als verglichener Baustein
PGA113 AKTIV Zero-Drift, 100-µV-Offset, 12-nV/√Hz-Rauschen, programmierbarer RRO-Verstärker (Scope-Gain) mit 2-Ka PGA113 is a similar device but not the same functionality, offering wider gain range, 4 calibration channels, 2 channel MUX, and SPI interface

Technische Dokumentation

star =Von TI ausgewählte Top-Empfehlungen für dieses Produkt
Keine Ergebnisse gefunden. Bitte geben Sie einen anderen Begriff ein und versuchen Sie es erneut.
Alle anzeigen 13
Typ Titel Datum
* Data sheet Single-Supply, Auto-Zero Sensor Amplifier with Programmable Gain and Offset datasheet (Rev. B) 22 Dez 2010
Application brief Multichannel Analog Input Modules for PLC Equipment 04 Jan 2019
EVM User's guide PGA308EVM User's Guide (Rev. A) 22 Sep 2016
EVM User's guide Multi-Cal-System Evaluation Module User's Guide (Rev. B) 15 Sep 2016
User guide PGA308 User's Guide (Rev. B) 27 Jan 2012
User guide Multi-Cal-PGA308 System User Guide 29 Apr 2011
User guide Multi-Cal-Interface User's Guide 09 Sep 2010
User guide Multi-Cal-Slave User's Guide 09 Sep 2010
User guide Multi-Cal-Cable User's Guide 08 Sep 2010
User guide Multi-Cal-Master User's Guide 22 Aug 2010
User guide Multi-Cal-Test Users Guide 22 Aug 2010
User guide tioScript Editor Users Guide 26 Aug 2008
User guide USB DAQ Platform User's Guide 20 Mär 2008

Design und Entwicklung

Weitere Bedingungen oder erforderliche Ressourcen enthält gegebenenfalls die Detailseite, die Sie durch Klicken auf einen der unten stehenden Titel erreichen.

Evaluierungsplatine

MULTI-CAL-SYSTEM — Multi-Cal-System-Basis-Starterkit

The Multi-Cal-System is a system of evaluation modules and accessories that can be used to calibrate multiple PGA308 sensor modules. The Multi-Cal-System can be configured to calibrate from 8 to 64 PGA308s simultaneously. The key component of the Multi-Cal-System is the Multi-Cal-System Starter (...)

Benutzerhandbuch: PDF
Evaluierungsplatine

PGA308EVM — PGA308-Evaluierungsmodul

The PGA308EVM key hardware consists of two boards, PGA308 Test Board and USB DAQ Platform. The PGA308 Test Board contains the PGA308, terminal strips for external connections, several jumpers for device configuration, and support circuitry. The PGA308 Test Board can be used to fully test your (...)

Benutzerhandbuch: PDF
Support-Software

SBOC256 PGA308EVM Source Code

Unterstützte Produkte und Hardware

Unterstützte Produkte und Hardware

Produkte
Verstärker mit programmierbarer Verstärkung (PGA) und mit variabler Verstärkung (VGA)
PGA308 Verstärker mit Autozero-Sensor; einzelne Stromversorgung, Verstärkung und Offset programmierbar
Hardware-Entwicklung
Evaluierungsplatine
PGA308EVM PGA308-Evaluierungsmodul
Support-Software

SBOC257 PGA308EVM Software

Unterstützte Produkte und Hardware

Unterstützte Produkte und Hardware

Produkte
Verstärker mit programmierbarer Verstärkung (PGA) und mit variabler Verstärkung (VGA)
PGA308 Verstärker mit Autozero-Sensor; einzelne Stromversorgung, Verstärkung und Offset programmierbar
Hardware-Entwicklung
Evaluierungsplatine
PGA308EVM PGA308-Evaluierungsmodul
Support-Software

SBOC390 Multi-Cal-PGA308 System Software

Unterstützte Produkte und Hardware

Unterstützte Produkte und Hardware

Produkte
Verstärker mit programmierbarer Verstärkung (PGA) und mit variabler Verstärkung (VGA)
PGA308 Verstärker mit Autozero-Sensor; einzelne Stromversorgung, Verstärkung und Offset programmierbar
Support-Software

SBOC391 Multi-Cal-PGA308 System Source Code

Unterstützte Produkte und Hardware

Unterstützte Produkte und Hardware

Produkte
Verstärker mit programmierbarer Verstärkung (PGA) und mit variabler Verstärkung (VGA)
PGA308 Verstärker mit Autozero-Sensor; einzelne Stromversorgung, Verstärkung und Offset programmierbar
Schaltplan

PGA308EVM Schematic

SBOR004.PDF (45 KB)
Schaltplan

Multi-Cal-Master Schematics

SBOR011.ZIP (585 KB)
Schaltplan

Multi-Cal-Slave Schematic

SBOR015.PDF (535 KB)
Simulationstool

PSPICE-FOR-TI — PSpice® für TI Design-und Simulationstool

PSpice® für TI ist eine Design- und Simulationsumgebung, welche Sie dabei unterstützt, die Funktionalität analoger Schaltungen zu evaluieren. Diese voll ausgestattete Design- und Simulationssuite verwendet eine analoge Analyse-Engine von Cadence®. PSpice für TI ist kostenlos erhältlich und (...)
Simulationstool

TINA-TI — SPICE-basiertes analoges Simulationsprogramm

TINA-TI provides all the conventional DC, transient and frequency domain analysis of SPICE and much more. TINA has extensive post-processing capability that allows you to format results the way you want them. Virtual instruments allow you to select input waveforms and probe circuit nodes voltages (...)
Benutzerhandbuch: PDF
Gehäuse Pins CAD-Symbole, Footprints und 3D-Modelle
VSON (DRK) 10 Ultra Librarian
VSSOP (DGS) 10 Ultra Librarian

Bestellen & Qualität

Beinhaltete Information:
  • RoHS
  • REACH
  • Bausteinkennzeichnung
  • Blei-Finish/Ball-Material
  • MSL-Rating / Spitzenrückfluss
  • MTBF-/FIT-Schätzungen
  • Materialinhalt
  • Qualifikationszusammenfassung
  • Kontinuierliches Zuverlässigkeitsmonitoring
Beinhaltete Information:
  • Werksstandort
  • Montagestandort

Support und Schulungen

TI E2E™-Foren mit technischem Support von TI-Ingenieuren

Inhalte werden ohne Gewähr von TI und der Community bereitgestellt. Sie stellen keine Spezifikationen von TI dar. Siehe Nutzungsbedingungen.

Bei Fragen zu den Themen Qualität, Gehäuse oder Bestellung von TI-Produkten siehe TI-Support. ​​​​​​​​​​​​​​

Videos