Cell chemistry Primary Lithium Number of series cells 2-4 Cells Communication interface HDQ Battery capacity (min) (mAh) 1000 Battery capacity (max) (mAh) 12000 Implementation Pack External capacity indication LED Features Coulomb Counter Operating temperature range (°C) -20 to 70 Rating Catalog
Cell chemistry Primary Lithium Number of series cells 2-4 Cells Communication interface HDQ Battery capacity (min) (mAh) 1000 Battery capacity (max) (mAh) 12000 Implementation Pack External capacity indication LED Features Coulomb Counter Operating temperature range (°C) -20 to 70 Rating Catalog
SOIC (D) 16 59.4 mm² 9.9 x 6
  • Accurate measurement of available capacity in Lithium primary batteries such as Lithium Sulphur Dioxide and Lithium Manganese Dioxide
  • Provides a low-cost battery monitor solution for pack integration
    • Complete circuit can fit less than 1 square inch of PCB space
    • Low operating current
    • Less than 100nA of data retention current
  • Single-wire communication interface (HDQ bus) for critical battery parameters
  • Communicates remaining capacity with direct drive of LEDs in 3 selectable modes
  • Measurements automatically compensated for discharge rate and temperature
  • 16-pin narrow SOIC
  • Accurate measurement of available capacity in Lithium primary batteries such as Lithium Sulphur Dioxide and Lithium Manganese Dioxide
  • Provides a low-cost battery monitor solution for pack integration
    • Complete circuit can fit less than 1 square inch of PCB space
    • Low operating current
    • Less than 100nA of data retention current
  • Single-wire communication interface (HDQ bus) for critical battery parameters
  • Communicates remaining capacity with direct drive of LEDs in 3 selectable modes
  • Measurements automatically compensated for discharge rate and temperature
  • 16-pin narrow SOIC

The bq2052 Lithium Primary Gas Gauge IC is intended for battery-pack or in system installation to maintain an accurate record of available battery capacity. The IC monitors a voltage drop across a sense resistor connected in series with the cells to determine discharge activity of the battery. The bq2052 applies compensations for battery temperature and discharge rate to the available charge counter to provide available capacity information across a wide range of operating conditions.

Compensated available capacity may be directly indicated using an LED display. The LED display is programmable and can be configured as two, four, or five segments. These segments are used to depict available battery capacity. The bq2052 supports a single-wire serial communications link to an external microcontroller. The link allows the microcontroller to read and write the internal registers of the bq2052. The internal registers include available battery capacity, voltage, temperature, current, and battery status. The controller may also overwrite some of the bq2052 gas gauge data registers.

The bq2052 can operate from the batteries in the pack. The REF output and an external FET provide a simple, inexpensive voltage regulator to supply power to the circuit from the cells.

The bq2052 Lithium Primary Gas Gauge IC is intended for battery-pack or in system installation to maintain an accurate record of available battery capacity. The IC monitors a voltage drop across a sense resistor connected in series with the cells to determine discharge activity of the battery. The bq2052 applies compensations for battery temperature and discharge rate to the available charge counter to provide available capacity information across a wide range of operating conditions.

Compensated available capacity may be directly indicated using an LED display. The LED display is programmable and can be configured as two, four, or five segments. These segments are used to depict available battery capacity. The bq2052 supports a single-wire serial communications link to an external microcontroller. The link allows the microcontroller to read and write the internal registers of the bq2052. The internal registers include available battery capacity, voltage, temperature, current, and battery status. The controller may also overwrite some of the bq2052 gas gauge data registers.

The bq2052 can operate from the batteries in the pack. The REF output and an external FET provide a simple, inexpensive voltage regulator to supply power to the circuit from the cells.

Descargar Ver vídeo con transcripción Video

Documentación técnica

star =Principal documentación para este producto seleccionada por TI
No se encontraron resultados. Borre su búsqueda y vuelva a intentarlo.
Ver todo 2
Tipo Título Fecha
* Data sheet Gas Gauge IC for Lithium Primary Cells datasheet 05 sep 1999
Application note HDQ Communication Basics for TI Battery Monitor ICs 16 may 2001

Diseño y desarrollo

Para conocer los términos adicionales o los recursos necesarios, haga clic en cualquier título de abajo para ver la página de detalles cuando esté disponible.

Encapsulado Pines Símbolos CAD, huellas y modelos 3D
SOIC (D) 16 Ultra Librarian

Pedidos y calidad

Información incluida:
  • RoHS
  • REACH
  • Marcado del dispositivo
  • Acabado de plomo/material de la bola
  • Clasificación de nivel de sensibilidad a la humedad (MSL) / reflujo máximo
  • Estimaciones de tiempo medio entre fallas (MTBF)/fallas en el tiempo (FIT)
  • Contenido del material
  • Resumen de calificaciones
  • Monitoreo continuo de confiabilidad
Información incluida:
  • Lugar de fabricación
  • Lugar de ensamblaje

Soporte y capacitación

Foros de TI E2E™ con asistencia técnica de los ingenieros de TI

El contenido lo proporcionan “tal como está” TI y los colaboradores de la comunidad y no constituye especificaciones de TI. Consulte los términos de uso.

Si tiene preguntas sobre la calidad, el paquete o el pedido de productos de TI, consulte el soporte de TI. ​​​​​​​​​​​​​​

Videos