Detalles del producto

Number of steps 64 Number of channels 2 End-to-end resistance (typ) (Ω) 2500 Resistance taper Log End-to-end resistance tolerance (max) (%) 30 Interface type Parallel Memory Volatile Bandwidth (MHz) 8 Wiper resistance (typ) (Ω) 420 Operating temperature range (°C) -40 to 85 Rating Catalog
Number of steps 64 Number of channels 2 End-to-end resistance (typ) (Ω) 2500 Resistance taper Log End-to-end resistance tolerance (max) (%) 30 Interface type Parallel Memory Volatile Bandwidth (MHz) 8 Wiper resistance (typ) (Ω) 420 Operating temperature range (°C) -40 to 85 Rating Catalog
TSSOP (PW) 16 32 mm² 5 x 6.4
  • Adjustable Gain From 23.25 dB to –24 dB
  • 64-Tap Positions With 0.75 dB Per Step
  • Supports 8-MHz Analog Bandwidth
  • Operating Range up to –4-V VEE/+4-V VDD
  • 100-µA Maximum Static Supply Current
  • ±30% End-to-End Resistance Tolerance
  • Absolute Tolerance of ±0.3 dB
  • Operating Temperature Range From
    –40°C to 85°C
  • ESD Performance Tested Per JESD 22
    • 2000-V Human-Body Model
      (A114-B,Class II)
  • APPLICATIONS
    • Tandem Adjustable Feedback and Gain
      Resistors for Operational Amplifers

  • Adjustable Gain From 23.25 dB to –24 dB
  • 64-Tap Positions With 0.75 dB Per Step
  • Supports 8-MHz Analog Bandwidth
  • Operating Range up to –4-V VEE/+4-V VDD
  • 100-µA Maximum Static Supply Current
  • ±30% End-to-End Resistance Tolerance
  • Absolute Tolerance of ±0.3 dB
  • Operating Temperature Range From
    –40°C to 85°C
  • ESD Performance Tested Per JESD 22
    • 2000-V Human-Body Model
      (A114-B,Class II)
  • APPLICATIONS
    • Tandem Adjustable Feedback and Gain
      Resistors for Operational Amplifers

The TPL8002-25 is a programmable resistor device implementing two digital potentiometers with 64 wiper positions each that are tandem controlled through a 6-bit parallel interface. The device has fixed wiper resistances at the respective wiper contacts that tap the potentiometer resistors at a point determined by the binary code present at its digital inputs.

The resistive wiper tap terminals, RSW, of the TPL8002-25 are typically connected to the inverting inputs (–) of an external differential path inverting operational amplifier configuration, with the non-inverting inputs (+) connected through to ground. The application’s differential input to the configuration is the device’s RG terminals. The differential output of the external operational amplifiers is connected to the device’s RF terminals, and thus becomes the differential output of the application configuration.

The resistance between the wiper contacts and the end points RG and RF of the TPL8002-25 provides a logarithmic gain/attenuation response of the configuration. With a digital code of decimal 0 (b000000) the configuration has an inverting maximum attenuation of –24 dB. With a digital code of decimal 32 (b100000) the configuration has inverting unity gain of 0.00 dB. With a digital code of decimal 63 (b111111) the configuration has an inverting maximum gain of +23.25 dB. The response of the configuration with respect to the digital code varies in fixed steps of 0.75 dB.

The TPL8002-25 is a programmable resistor device implementing two digital potentiometers with 64 wiper positions each that are tandem controlled through a 6-bit parallel interface. The device has fixed wiper resistances at the respective wiper contacts that tap the potentiometer resistors at a point determined by the binary code present at its digital inputs.

The resistive wiper tap terminals, RSW, of the TPL8002-25 are typically connected to the inverting inputs (–) of an external differential path inverting operational amplifier configuration, with the non-inverting inputs (+) connected through to ground. The application’s differential input to the configuration is the device’s RG terminals. The differential output of the external operational amplifiers is connected to the device’s RF terminals, and thus becomes the differential output of the application configuration.

The resistance between the wiper contacts and the end points RG and RF of the TPL8002-25 provides a logarithmic gain/attenuation response of the configuration. With a digital code of decimal 0 (b000000) the configuration has an inverting maximum attenuation of –24 dB. With a digital code of decimal 32 (b100000) the configuration has inverting unity gain of 0.00 dB. With a digital code of decimal 63 (b111111) the configuration has an inverting maximum gain of +23.25 dB. The response of the configuration with respect to the digital code varies in fixed steps of 0.75 dB.

Descargar Ver vídeo con transcripción Video

Productos similares que pueden interesarle

open-in-new Comparar alternativas
Funcionalidad similar a la del dispositivo comparado
TPL1401 ACTIVO Potenciómetro digital de alta precisión de 256 toques con limpiador de búfer 256-tap digital potentiometer (digipot) with buffered wiper

Documentación técnica

star =Principal documentación para este producto seleccionada por TI
No se encontraron resultados. Borre su búsqueda y vuelva a intentarlo.
Ver todo 2
Tipo Título Fecha
* Data sheet Tandem 64 Tap Digital Potentiometer datasheet 17 ago 2009
Application brief Replacing Digital Potentiometers with Precision DACs 03 jul 2019

Diseño y desarrollo

Para conocer los términos adicionales o los recursos necesarios, haga clic en cualquier título de abajo para ver la página de detalles cuando esté disponible.

Herramienta de simulación

PSPICE-FOR-TI — PSpice® para herramienta de diseño y simulación de TI

PSpice® for TI is a design and simulation environment that helps evaluate functionality of analog circuits. This full-featured, design and simulation suite uses an analog analysis engine from Cadence®. Available at no cost, PSpice for TI includes one of the largest model libraries in the (...)
Herramienta de simulación

TINA-TI — Programa de simulación analógica basado en SPICE

TINA-TI provides all the conventional DC, transient and frequency domain analysis of SPICE and much more. TINA has extensive post-processing capability that allows you to format results the way you want them. Virtual instruments allow you to select input waveforms and probe circuit nodes voltages (...)
Guía del usuario: PDF
Encapsulado Pines Símbolos CAD, huellas y modelos 3D
TSSOP (PW) 16 Ultra Librarian

Pedidos y calidad

Información incluida:
  • RoHS
  • REACH
  • Marcado del dispositivo
  • Acabado de plomo/material de la bola
  • Clasificación de nivel de sensibilidad a la humedad (MSL) / reflujo máximo
  • Estimaciones de tiempo medio entre fallas (MTBF)/fallas en el tiempo (FIT)
  • Contenido del material
  • Resumen de calificaciones
  • Monitoreo continuo de confiabilidad
Información incluida:
  • Lugar de fabricación
  • Lugar de ensamblaje

Soporte y capacitación

Foros de TI E2E™ con asistencia técnica de los ingenieros de TI

El contenido lo proporcionan “tal como está” TI y los colaboradores de la comunidad y no constituye especificaciones de TI. Consulte los términos de uso.

Si tiene preguntas sobre la calidad, el paquete o el pedido de productos de TI, consulte el soporte de TI. ​​​​​​​​​​​​​​

Videos