ISO1044

AKTIV

Isolierter CAN FD-Transceiver in kleinem Gehäuse

Produktdetails

Rating Catalog Isolation rating Basic Data rate (max) (Mbps) 5 Working isolation voltage (VIOWM) (Vrms) 459 Surge isolation voltage (VIOSM) (VPK) 5000, 8000 Transient isolation voltage (VIOTM) (VPK) 4242 Withstand isolation voltage (VISO) (Vrms) 3000 CMTI (min) (kV/µs) 85 Supply voltage (V) 1.71 to 5.5, 4.5 to 5.5 Bus fault voltage (V) -58 to 58 Common-mode voltage (V) -12 to 12 Operating temperature range (°C) -40 to 125
Rating Catalog Isolation rating Basic Data rate (max) (Mbps) 5 Working isolation voltage (VIOWM) (Vrms) 459 Surge isolation voltage (VIOSM) (VPK) 5000, 8000 Transient isolation voltage (VIOTM) (VPK) 4242 Withstand isolation voltage (VISO) (Vrms) 3000 CMTI (min) (kV/µs) 85 Supply voltage (V) 1.71 to 5.5, 4.5 to 5.5 Bus fault voltage (V) -58 to 58 Common-mode voltage (V) -12 to 12 Operating temperature range (°C) -40 to 125
SOIC (D) 8 29.4 mm² 4.9 x 6
  • Meets the ISO 11898-2:2016 physical layer standard
  • Supports classic CAN up to 1 Mbps and FD (flexible data rate) up to 5 Mbps
  • Protection features
    • DC Bus Fault Protection Voltage: ±58 V
    • IEC ESD tolerance on bus pins: ±8 kV
    • HBM ESD tolerance on bus pins: ±10 kV
    • Driver dominant time out (TXD DTO)
    • Undervoltage protection on VCC1 and VCC2
  • Common-mode voltage range: ±12 V
  • Ideal passive, high impedance bus terminals when unpowered
  • High CMTI: 85 kV/µs minimum
  • VCC1 voltage range: 1.71 V to 5.5 V
    • Supports 1.8-V, 2.5-V, 3.3-V and 5.0-V logic interface to the CAN controller
  • VCC2 voltage range: 4.5 V to 5.5 V
  • Robust electromagnetic compatibility (EMC)
    • System-Level ESD, EFT, and surge Immunity
    • Low Emissions
  • Ambient temperature range: –40°C to +125°C
  • 8-SOIC package
  • Safety-related certifications:
    • All certifications planned
    • VDE reinforced insulation per DIN VDE V 0884-11:2017-01
    • UL 1577 component recognition program
    • IEC 60950-1, IEC 62368-1, IEC 61010-1 and GB 4943.1-2011 certifications
  • Meets the ISO 11898-2:2016 physical layer standard
  • Supports classic CAN up to 1 Mbps and FD (flexible data rate) up to 5 Mbps
  • Protection features
    • DC Bus Fault Protection Voltage: ±58 V
    • IEC ESD tolerance on bus pins: ±8 kV
    • HBM ESD tolerance on bus pins: ±10 kV
    • Driver dominant time out (TXD DTO)
    • Undervoltage protection on VCC1 and VCC2
  • Common-mode voltage range: ±12 V
  • Ideal passive, high impedance bus terminals when unpowered
  • High CMTI: 85 kV/µs minimum
  • VCC1 voltage range: 1.71 V to 5.5 V
    • Supports 1.8-V, 2.5-V, 3.3-V and 5.0-V logic interface to the CAN controller
  • VCC2 voltage range: 4.5 V to 5.5 V
  • Robust electromagnetic compatibility (EMC)
    • System-Level ESD, EFT, and surge Immunity
    • Low Emissions
  • Ambient temperature range: –40°C to +125°C
  • 8-SOIC package
  • Safety-related certifications:
    • All certifications planned
    • VDE reinforced insulation per DIN VDE V 0884-11:2017-01
    • UL 1577 component recognition program
    • IEC 60950-1, IEC 62368-1, IEC 61010-1 and GB 4943.1-2011 certifications

The ISO1044B device is a galvanically-isolated controller area network (CAN) transceiver that meets the specifications of the ISO11898-2 (2016) standard. The ISO1044B device offers ±58-V DC bus fault protection and ±12-V common-mode voltage range. The device supports up to 5-Mbps data rate in CAN FD mode allowing much faster transfer of payload compared to classic CAN. This device uses a silicon dioxide (SiO2) insulation barrier with a withstand voltage of 3000 VRMS and a working voltage of 450 VRMS. Electromagnetic compatibility has been significantly enhanced to enable system-level ESD, EFT, surge, and emissions compliance. Used in conjunction with isolated power supplies, the device protects against high voltage, and prevents noise currents from the bus from entering the local ground. The ISO1044B device supports a wide ambient temperature range of –40°C to +125°C. The device is available in the small SOIC-8 (D) package which significantly reduces the solution size compared to a traditional approach using optocouplers to isolate the CAN transceiver.

The ISO1044B device is a galvanically-isolated controller area network (CAN) transceiver that meets the specifications of the ISO11898-2 (2016) standard. The ISO1044B device offers ±58-V DC bus fault protection and ±12-V common-mode voltage range. The device supports up to 5-Mbps data rate in CAN FD mode allowing much faster transfer of payload compared to classic CAN. This device uses a silicon dioxide (SiO2) insulation barrier with a withstand voltage of 3000 VRMS and a working voltage of 450 VRMS. Electromagnetic compatibility has been significantly enhanced to enable system-level ESD, EFT, surge, and emissions compliance. Used in conjunction with isolated power supplies, the device protects against high voltage, and prevents noise currents from the bus from entering the local ground. The ISO1044B device supports a wide ambient temperature range of –40°C to +125°C. The device is available in the small SOIC-8 (D) package which significantly reduces the solution size compared to a traditional approach using optocouplers to isolate the CAN transceiver.

Herunterladen Video mit Transkript ansehen Video

Ähnliche Produkte, die für Sie interessant sein könnten

Selbe Funktionalität wie der verglichene Baustein bei gleicher Anschlussbelegung
ISO1042 AKTIV Isolierter CAN-Transceiver mit 70-V-Busfehlerschutz und flexibler Datenrate Higher isolation voltage isolated CAN transceiver with 70-V bus fault protection & flexible data rate

Technische Dokumentation

star =Von TI ausgewählte Top-Empfehlungen für dieses Produkt
Keine Ergebnisse gefunden. Bitte geben Sie einen anderen Begriff ein und versuchen Sie es erneut.
Alle anzeigen 16
Typ Titel Datum
* Data sheet ISO1044 Isolated CAN FD Transceiver in Small Package datasheet (Rev. A) 15 Jul 2020
Application note Top Design Questions About Isolated CAN Bus Design (Rev. B) PDF | HTML 24 Okt 2024
Certificate VDE Certificate for Reinforced Isolation for DIN EN IEC 60747-17 (Rev. S) 29 Feb 2024
Certificate CSA Certificate for ISO1044BD 16 Mär 2023
Certificate CQC Certificate for ISOxxD (Rev. A) 07 Feb 2023
Product overview Isolating a CAN Bus (Rev. A) PDF | HTML 13 Jan 2023
Certificate TUV Certificate for Isolation Devices (Rev. K) 05 Aug 2022
Certificate UL Certificate of Compliance File E181974 Vol 4 Sec 6 (Rev. P) 05 Aug 2022
Application brief Isolate Your CAN Systems Without Compromising on Performance or Space (Rev. F) PDF | HTML 04 Aug 2022
Application brief How to Design an Isolated CAN Port for Space-Constrained Industrial Applications (Rev. A) PDF | HTML 06 Jul 2022
White paper Why are Digital Isolators Certified to Meet Electrical Equipment Standards? 16 Nov 2021
White paper Distance Through Insulation: How Digital Isolators Meet Certification Requiremen PDF | HTML 11 Jun 2021
Application brief How to Isolate Signal and Power in Isolated CAN Systems (Rev. C) PDF | HTML 25 Mai 2021
Application note Isolated CAN Reference Design (Rev. E) 22 Jul 2020
User guide ISO1044DEVM Isolated CAN Evaluation Module PDF | HTML 20 Mär 2020
Technical article The hidden cost of optocouplers for isolated RS-485 and CAN designs PDF | HTML 28 Jan 2019

Design und Entwicklung

Weitere Bedingungen oder erforderliche Ressourcen enthält gegebenenfalls die Detailseite, die Sie durch Klicken auf einen der unten stehenden Titel erreichen.

Evaluierungsplatine

ISO1044DEVM — ISO1044 Isoliertes CAN-Transceiver-Evaluierungsmodul

ISO1044DEVM is an evaluation module used to evaluate the small package, basic isolation, high speed, robust EMC isolated CAN transceiver in the SOIC-8D package. The EVM features enough test points and jumper options to evaluate the device with minimal external components.
Benutzerhandbuch: PDF | HTML
Simulationsmodell

ISO1044BD IBIS Model

SLLM450.ZIP (81 KB) - IBIS Model
Gehäuse Pins CAD-Symbole, Footprints und 3D-Modelle
SOIC (D) 8 Ultra Librarian

Bestellen & Qualität

Beinhaltete Information:
  • RoHS
  • REACH
  • Bausteinkennzeichnung
  • Blei-Finish/Ball-Material
  • MSL-Rating / Spitzenrückfluss
  • MTBF-/FIT-Schätzungen
  • Materialinhalt
  • Qualifikationszusammenfassung
  • Kontinuierliches Zuverlässigkeitsmonitoring
Beinhaltete Information:
  • Werksstandort
  • Montagestandort

Empfohlene Produkte können Parameter, Evaluierungsmodule oder Referenzdesigns zu diesem TI-Produkt beinhalten.

Support und Schulungen

TI E2E™-Foren mit technischem Support von TI-Ingenieuren

Inhalte werden ohne Gewähr von TI und der Community bereitgestellt. Sie stellen keine Spezifikationen von TI dar. Siehe Nutzungsbedingungen.

Bei Fragen zu den Themen Qualität, Gehäuse oder Bestellung von TI-Produkten siehe TI-Support. ​​​​​​​​​​​​​​

Videos