제품 상세 정보

Package name DFN3030 Peak pulse power (8/20 μs) (max) (W) 1100 IEC 61000-4-5 (A) 27 Vrwm (V) 33 Breakdown voltage (min) (V) 34.4 Bi-/uni-directional Bi-directional Number of channels 1 IO capacitance (typ) (pF) 54 Clamping voltage (V) 40
Package name DFN3030 Peak pulse power (8/20 μs) (max) (W) 1100 IEC 61000-4-5 (A) 27 Vrwm (V) 33 Breakdown voltage (min) (V) 34.4 Bi-/uni-directional Bi-directional Number of channels 1 IO capacitance (typ) (pF) 54 Clamping voltage (V) 40
VSON (DRB) 8 9 mm² 3 x 3
  • Functional Safety-Capable
  • Protection against 1-kV, 42-Ω IEC 61000-4-5 surge test for industrial signal lines
  • Bidirectional polarity enables protection against bipolar signaling or miswiring conditions
  • Clamping voltage of 40 V at 27-A of 8/20-µs surge current
  • Standoff voltage: ±33 V
  • Small 3 mm × 3 mm SON footprint
  • Survives over 5,000 repetitive strikes of 25-A 8/20-µs surge current
  • Robust surge protection
    • IEC61000-4-5 (8/20 µs): 27 A
    • IEC61643-321 (10/1000 µs): 3 A
  • Low leakage current
    • 2.5-nA typical at 27°C
    • 450-nA maximum at 85°C
  • Low capacitance: 54 pF
  • Integrated level 4 IEC 61000-4-2 ESD protection
  • Functional Safety-Capable
  • Protection against 1-kV, 42-Ω IEC 61000-4-5 surge test for industrial signal lines
  • Bidirectional polarity enables protection against bipolar signaling or miswiring conditions
  • Clamping voltage of 40 V at 27-A of 8/20-µs surge current
  • Standoff voltage: ±33 V
  • Small 3 mm × 3 mm SON footprint
  • Survives over 5,000 repetitive strikes of 25-A 8/20-µs surge current
  • Robust surge protection
    • IEC61000-4-5 (8/20 µs): 27 A
    • IEC61643-321 (10/1000 µs): 3 A
  • Low leakage current
    • 2.5-nA typical at 27°C
    • 450-nA maximum at 85°C
  • Low capacitance: 54 pF
  • Integrated level 4 IEC 61000-4-2 ESD protection

The TVS3301 device shunts up to 27 A of IEC 61000-4-5 fault current to protect systems from high-power transients or lightning strikes. The device survives the common industrial signal line EMC requirement of 1-kV IEC 61000-4-5 open circuit voltage coupled through a 42-Ω impedance. The TVS3301 uses a feedback mechanism to ensure precise flat clamping during a fault, keeping system exposure lower than traditional TVS diodes. The tight voltage regulation allows designers to confidently select system components with a lower voltage tolerance, lowering system costs and complexity without sacrificing robustness. The TVS3301 has a ±33-V operating range to enable operation in systems that require protection against reverse wiring conditions.

In addition, the TVS3301 is available in a small SON footprint designed for space constrained applications, offering a significant size reduction compared to standard SMA and SMB packages. Low device leakage and capacitance ensure a minimal effect on the protected line. To ensure robust protection over the lifetime of the product, TI tests the TVS3301 against 5000 repetitive surge strikes at 125°C with no shift in device performance.

The TVS3301 is part of TI’s Flat-Clamp family of surge devices. For a deeper look at the Flat-Clamp family, refer to the Flat-Clamp Surge Protection Technology for Efficient System Protection white paper.

The TVS3301 device shunts up to 27 A of IEC 61000-4-5 fault current to protect systems from high-power transients or lightning strikes. The device survives the common industrial signal line EMC requirement of 1-kV IEC 61000-4-5 open circuit voltage coupled through a 42-Ω impedance. The TVS3301 uses a feedback mechanism to ensure precise flat clamping during a fault, keeping system exposure lower than traditional TVS diodes. The tight voltage regulation allows designers to confidently select system components with a lower voltage tolerance, lowering system costs and complexity without sacrificing robustness. The TVS3301 has a ±33-V operating range to enable operation in systems that require protection against reverse wiring conditions.

In addition, the TVS3301 is available in a small SON footprint designed for space constrained applications, offering a significant size reduction compared to standard SMA and SMB packages. Low device leakage and capacitance ensure a minimal effect on the protected line. To ensure robust protection over the lifetime of the product, TI tests the TVS3301 against 5000 repetitive surge strikes at 125°C with no shift in device performance.

The TVS3301 is part of TI’s Flat-Clamp family of surge devices. For a deeper look at the Flat-Clamp family, refer to the Flat-Clamp Surge Protection Technology for Efficient System Protection white paper.

다운로드 스크립트와 함께 비디오 보기 동영상

기술 자료

star =TI에서 선정한 이 제품의 인기 문서
검색된 결과가 없습니다. 검색어를 지우고 다시 시도하십시오.
13개 모두 보기
유형 직함 날짜
* Data sheet TVS3301 33-V Bidirectional Flat-Clamp Surge Protection Device datasheet (Rev. B) PDF | HTML 2022/09/01
Analog Design Journal 태양광 애플리케이션에서 확장 가능한 입력 바이패스 스위치로 이상적인 다이 오드 컨트롤러를 사용하는 방법 PDF | HTML 2024/06/27
Analog Design Journal 4mA~20mA 루프 전원 공급 트랜스미터 설계 PDF | HTML 2024/06/26
Selection guide System-Level ESD Protection Guide (Rev. D) 2022/09/07
Application note ESD Packaging and Layout Guide (Rev. B) PDF | HTML 2022/08/18
Functional safety information TVS3301 Functional Safety, FIT Rate, Failure Mode Distribution and Pin FMA PDF | HTML 2021/09/27
Application brief 16-Bit 8-Channel PLC Analog Input Module with High Voltage (±150 V) Common Mode 2020/04/27
Application brief Protecting I/O modules from surge events 2019/02/04
Application brief TVS Surge Rating: Power vs. Current 2018/11/12
White paper Demystifying surge protection 2018/11/06
User guide Flat Clamp TVS Evaluation Module—Adaptor Boards 2018/09/10
Application note How to select a Surge Diode 2018/08/29
Analog Design Journal Design Considerations for System-Level ESD Circuit Protection 2012/09/25

설계 및 개발

추가 조건 또는 필수 리소스는 사용 가능한 경우 아래 제목을 클릭하여 세부 정보 페이지를 확인하세요.

평가 보드

FLAT-CLAMP-TVS-EVM — TVSxx0x 정밀 서지 보호 다이오드 평가 모듈

The FLAT-CLAMP-TVS-EVM (Precision Surge Protection Diode Adaptor Board Evaluation Module) demonstrates the characteristics, operation, and use of the TVSxx0x family of devices. The TVSxx0x family of devices are precision clamps that keep ultra-low and flat clamping voltages during transient (...)
사용 설명서: PDF
TI.com에서 구매 불가
시뮬레이션 모델

TVS3301 PSpice Transient Model

SLVMCV9.ZIP (52 KB) - PSpice Model
레퍼런스 디자인

TIDA-010072 — 호흡기 애플리케이션을 위한 송풍기 및 밸브 제어 레퍼런스 설계

This reference design provides a compact system design capable of supporting motor acceleration and deceleration up to ±200 kRPM/s, which is a key requirement in many respirator applications. The design supports a number of offboard C2000 controllers including (...)
Design guide: PDF
회로도: PDF
레퍼런스 디자인

TIDA-010008 — 그리드 애플리케이션의 과도 차단 기능을 위한 평면 클램프 TV 기반 레퍼런스 설계

This reference design features multiple approaches for  protecting AC or DC analog input, DC analog output, AC or DC binary input, digital output with a high side or low side driver, LCD bias supply, USB interfaces (power and data) and onboard power supplies with 24, 12 or 5V input used in (...)
Design guide: PDF
회로도: PDF
레퍼런스 디자인

TIDA-010044 — 고장 보호 및 진단을 지원하는 NAMUR PLC 디지털 입력 레퍼런스 설계

The NAMUR proximity sensor is widely used in industrial control when a special requirement on maximum energy is to be fulfilled by the sensor. This in turn dictates special requirements on the PLC digital input designed to interface with such sensor with regard to accuracy, and reliability. This (...)
Design guide: PDF
회로도: PDF
패키지 CAD 기호, 풋프린트 및 3D 모델
VSON (DRB) 8 Ultra Librarian

주문 및 품질

포함된 정보:
  • RoHS
  • REACH
  • 디바이스 마킹
  • 납 마감/볼 재질
  • MSL 등급/피크 리플로우
  • MTBF/FIT 예측
  • 물질 성분
  • 인증 요약
  • 지속적인 신뢰성 모니터링
포함된 정보:
  • 팹 위치
  • 조립 위치

권장 제품에는 본 TI 제품과 관련된 매개 변수, 평가 모듈 또는 레퍼런스 디자인이 있을 수 있습니다.

지원 및 교육

TI 엔지니어의 기술 지원을 받을 수 있는 TI E2E™ 포럼

콘텐츠는 TI 및 커뮤니티 기고자에 의해 "있는 그대로" 제공되며 TI의 사양으로 간주되지 않습니다. 사용 약관을 참조하십시오.

품질, 패키징, TI에서 주문하는 데 대한 질문이 있다면 TI 지원을 방문하세요. ​​​​​​​​​​​​​​

동영상