Produktdetails

Device type Voltage sensing Peak-to-peak input voltage range (V) 2 Isolation rating Reinforced Withstand isolation voltage (VISO) (Vrms) 5000 Working isolation voltage (VIOWM) (Vrms) 1500 Transient isolation voltage (VIOTM) (VPK) 7000 CMTI (min) (kV/µs) 15, 75 Creepage (min) (mm) 8.5 Clearance (min) (mm) 8.5 Input offset (±) (max) (V) 0.0015, 0.0099 Input offset drift (±) (typ) (µV/°C) 3, 20 Rating Catalog Operating temperature range (°C) -55 to 125
Device type Voltage sensing Peak-to-peak input voltage range (V) 2 Isolation rating Reinforced Withstand isolation voltage (VISO) (Vrms) 5000 Working isolation voltage (VIOWM) (Vrms) 1500 Transient isolation voltage (VIOTM) (VPK) 7000 CMTI (min) (kV/µs) 15, 75 Creepage (min) (mm) 8.5 Clearance (min) (mm) 8.5 Input offset (±) (max) (V) 0.0015, 0.0099 Input offset drift (±) (typ) (µV/°C) 3, 20 Rating Catalog Operating temperature range (°C) -55 to 125
SOIC (DWV) 8 67.275 mm² 5.85 x 11.5
  • 2-V, high-impedance input voltage range optimized for isolated voltage measurement
  • Fixed gain: 1
  • Low DC errors:
    • AMC1311:
      • Offset error: ±9.9 mV (maximum)
      • Offset drift: ±20 µV/°C (typical)
      • Gain error: ±1% (maximum)
      • Gain drift: ±30 ppm/°C (typical)
    • AMC1311B:
      • Offset error: ±1.5 mV (maximum)
      • Offset drift: ±10 µV/°C (maximum)
      • Gain error: ±0.2% (maximum)
      • Gain drift: ±40 ppm/°C (maximum)
    • Nonlinearity: 0.04% (maximum)
  • 3.3-V operation on high-side ( AMC1311B)
  • High CMTI: 100 kV/µs (minimum) ( AMC1311B)
  • Missing high-side supply indication
  • Safety-related certifications:
    • 7000-VPK reinforced isolation per DIN EN IEC 60747-17 (VDE 0884-17)
    • 5000-VRMS isolation for 1 minute per UL1577
    • Fully specified over the extended industrial temperature range: –40°C to +125°C
  • 2-V, high-impedance input voltage range optimized for isolated voltage measurement
  • Fixed gain: 1
  • Low DC errors:
    • AMC1311:
      • Offset error: ±9.9 mV (maximum)
      • Offset drift: ±20 µV/°C (typical)
      • Gain error: ±1% (maximum)
      • Gain drift: ±30 ppm/°C (typical)
    • AMC1311B:
      • Offset error: ±1.5 mV (maximum)
      • Offset drift: ±10 µV/°C (maximum)
      • Gain error: ±0.2% (maximum)
      • Gain drift: ±40 ppm/°C (maximum)
    • Nonlinearity: 0.04% (maximum)
  • 3.3-V operation on high-side ( AMC1311B)
  • High CMTI: 100 kV/µs (minimum) ( AMC1311B)
  • Missing high-side supply indication
  • Safety-related certifications:
    • 7000-VPK reinforced isolation per DIN EN IEC 60747-17 (VDE 0884-17)
    • 5000-VRMS isolation for 1 minute per UL1577
    • Fully specified over the extended industrial temperature range: –40°C to +125°C

The AMC1311 is a precision, isolated amplifier with an output separated from the input circuitry by a capacitive isolation barrier that is highly resistant to magnetic interference. This barrier is certified to provide reinforced galvanic isolation of up to 5 kVRMS according to DIN EN IEC 60747-17 (VDE 0884-17) and UL1577 and supports a working voltage of up to 1500 VRMS.

The isolation barrier separates parts of the system that operate on different common-mode voltage levels and protects the low-voltage side from voltages that can cause electrical damage or be harmful to an operator.

The high-impedance input of the AMC1311 is optimized for connection to high-impedance resistive dividers or any other high-impedance voltage signal source. The excellent DC accuracy and low temperature drift support accurate, isolated voltage sensing and control in closed-loop systems. The integrated missing high-side supply voltage detection feature simplifies system-level design and diagnostics.

The AMC1311 is offered with two performance grade options: the AMC1311B is specified over the extended industrial temperature range of –55°C to +125°C, and the AMC1311 is specified for operation at –40°C to +125°C.

The AMC1311 is a precision, isolated amplifier with an output separated from the input circuitry by a capacitive isolation barrier that is highly resistant to magnetic interference. This barrier is certified to provide reinforced galvanic isolation of up to 5 kVRMS according to DIN EN IEC 60747-17 (VDE 0884-17) and UL1577 and supports a working voltage of up to 1500 VRMS.

The isolation barrier separates parts of the system that operate on different common-mode voltage levels and protects the low-voltage side from voltages that can cause electrical damage or be harmful to an operator.

The high-impedance input of the AMC1311 is optimized for connection to high-impedance resistive dividers or any other high-impedance voltage signal source. The excellent DC accuracy and low temperature drift support accurate, isolated voltage sensing and control in closed-loop systems. The integrated missing high-side supply voltage detection feature simplifies system-level design and diagnostics.

The AMC1311 is offered with two performance grade options: the AMC1311B is specified over the extended industrial temperature range of –55°C to +125°C, and the AMC1311 is specified for operation at –40°C to +125°C.

Herunterladen Video mit Transkript ansehen Video

Ähnliche Produkte, die für Sie interessant sein könnten

Drop-In-Ersatz mit gegenüber dem verglichenen Baustein verbesserter Funktionalität
AMC1336 AKTIV ±1-V-Eingang, Präzisions-Spannungsmessung verstärkter isolierter Modulator Modulator output version
AMC1351 AKTIV 0-V- bis 5-V-Eingang, Präzisions-Spannungsmessung Verstärker mit verstärkter Isolierung Larger input voltage range, 0-5V
Ähnliche Funktionalität wie verglichener Baustein
AMC1411 AKTIV Verstärker mit verstärkter Isolierung, mit präziser Spannungsmessung und hohem CMTI, 2 V Eingangs Increased creapage and clearance
AMC3330 AKTIV Isolierter, verstärkter Verstärker mit einem Eingang von ±1 V mit integriertem DC/DC-Wandler für die Added feature: integrated high voltage domain input power supply

Technische Dokumentation

star =Von TI ausgewählte Top-Empfehlungen für dieses Produkt
Keine Ergebnisse gefunden. Bitte geben Sie einen anderen Begriff ein und versuchen Sie es erneut.
Alle anzeigen 16
Typ Titel Datum
* Data sheet AMC1311x High-Impedance, 2-V Input, Reinforced Isolated Amplifiers datasheet (Rev. C) PDF | HTML 06 Jun 2022
Application note Entwicklung einer Bootstrap-Ladepumpen-Stromversorgung für einen isolierten Verstärker PDF | HTML 19 Aug 2024
Application brief Shunt-Widerstandsauswahl für isolierte Datenwandler PDF | HTML 15 Aug 2024
White paper Beste EMI-Leistung in ihrer Klasse bei Strahlungsemissionen mit isolierten Verstärkern (Rev. A) PDF | HTML 17 Jul 2024
Analog Design Journal Isolierte Spannungserfassung in ACMotorantrieben PDF | HTML 11 Jul 2024
White paper Vergleich isolierter Verstärker und isolierter Modulatoren (Rev. B) PDF | HTML 02 Jul 2024
Application brief Anschluss eines Differenzialausgangsverstärkers (isoliert) an einen A/D-Wandler mit unsymmetrischem Eingang (Rev. B) PDF | HTML 27 Jun 2024
Circuit design Isolierter Spannungssensorschaltkreis mit ±480 V und Differenzausgang (Rev. A) PDF | HTML 24 Jun 2024
Certificate VDE Certificate for Reinforced Isolation for DIN EN IEC 60747-17 (Rev. S) 29 Feb 2024
White paper Understanding failure modes in isolators (Rev. B) PDF | HTML 29 Jan 2024
White paper Addressing High-Volt Design Challenges w/ Reliable and Affordable Isolation Tech (Rev. C) PDF | HTML 26 Sep 2023
Certificate UL Certificate of Compliance Vol4 Sec5 E181974 (Rev. A) 23 Jan 2023
Circuit design ±480-V isolated voltage-sensing circuit with differential output 24 Jan 2019
Certificate Optical Isolating Devices UL 1577 Certificate of Compliance 07 Mär 2018
EVM User's guide AMC1311EVM User's Guide 13 Nov 2017
Selection guide Understanding isolation terminology and relevance 23 Mai 2016

Design und Entwicklung

Weitere Bedingungen oder erforderliche Ressourcen enthält gegebenenfalls die Detailseite, die Sie durch Klicken auf einen der unten stehenden Titel erreichen.

Evaluierungsplatine

AMC1311EVM — AMC1311-Evaluierungsmodul

The AMC1311 device is a high-voltage isolation amplifier with a differential output separated from the input interface circuitry by a silicon dioxide (SiO2) isolation barrier. The isolation barrier provides galvanic isolation of up to 7000 VPEAK.  When used in combination with TLV6001, the (...)

Benutzerhandbuch: PDF
Simulationsmodell

AMC1311 PSpice Model (Rev. A)

SBAM385A.ZIP (5 KB) - PSpice Model
Simulationsmodell

AMC1311 TINA-TI Reference Design (Rev. B)

SBAM366B.ZIP (325 KB) - TINA-TI Reference Design
Simulationsmodell

AMC1311 TINA-TI Spice Model (Rev. A)

SBAM367A.ZIP (14 KB) - TINA-TI Spice Model
Berechnungstool

SBAR013 Isolated Amplifier Voltage Sensing Excel Calculator

This calculator provides estimates of the errors associated with using isolation amplifier devices in a voltage sensing configuration.
Unterstützte Produkte und Hardware

Unterstützte Produkte und Hardware

Produkte
Trennverstärker
AMC1202 Isolierter Basisverstärker mit ±50-mV-Eingang und präziser Strommessung AMC1211-Q1 Isolierter Basisverstärker mit präziser Spannungsmessung, 2 V Eingangsspannung AMC1300 &Plusmn;250-mV-Eingang, Präzisions-Strommessverstärker mit verstärkter Isolierung AMC1300B-Q1 Präzisions-Verstärker für die Automobilindustrie, ±250 mV-Eingang, verstärkt isoliert AMC1301 Präziser Verstärker mit verstärkter Isolierung, ±250 mV-Eingangsspannung zur Strommessung AMC1301-Q1 250-mV-isolierter Präzisionsverstärker mit ±Eingängen und 3µs Verzögerung für die Automobilindustrie AMC1302 &Plusmn;50-mV-Eingang, Präzisions-Strommessverstärker mit verstärkter Isolierung AMC1302-Q1 Präzisions-Verstärker für die Automobilindustrie, ±50 mV-Eingang, verstärkt isoliert AMC1311 Verstärker mit verstärkter Isolierung, mit präziser Spannungsmessung, 2 V Eingangsspannung AMC1311-Q1 Verstärker mit verstärkter Isolierung für die Automobilindustrie mit 2-V-Eingang für die Spannung AMC1350 &Plusmn;5-V-Eingang, Präzisions-Spannungsmessung verstärkter isolierter Verstärker AMC1351 0-V- bis 5-V-Eingang, Präzisions-Spannungsmessung Verstärker mit verstärkter Isolierung AMC1400 &Plusmn;250-mV-Eingang, Präzisions-Strommessverstärker mit verstärkter Isolierung mit hohem CMTI< AMC1400-Q1 Reinforced-Trennverstärker für die Automobilindustrie, ±250-mV Eingangsspannung, mit hohem CMTI zur AMC1411 Verstärker mit verstärkter Isolierung, mit präziser Spannungsmessung und hohem CMTI, 2 V Eingangs AMC1411-Q1 Reinforced-Trennverstärker für die Automobilindustrie, 2 V Eingangsspannung, mit hohem CMTI zur präz AMC3301 Isolierter, verstärkter Präzisionsverstärker mit einem Eingang von ±250 mV mit integriertem DC/DC-Wa AMC3301-Q1 Verstärker mit ±250 mV-Eingang, verstärkt isoliert, mit int. für die präzise Strommessung in der Aut AMC3302 Isolierter, verstärkter Präzisionsverstärker mit einem Eingang von ±50 mV mit integriertem DC/DC-Wan AMC3302-Q1 Verstärker mit ±50 mV-Eingang, verstärkt isoliert, mit int. für die präzise Strommessung in der Auto AMC3330 Isolierter, verstärkter Verstärker mit einem Eingang von ±1 V mit integriertem DC/DC-Wandler für die AMC3330-Q1 Reinforced-Trennverstärker für die Automobilindustrie, ±1-V Eingang, mit int. zur präzisen Spannungs ISO224 &Plusmn;12-V-Eingang, Präzisions-Spannungsmessung verstärkter isolierter Verstärker
Berechnungstool

SBAR020 Isolated Amplifier Current Sensing Excel Calculator

This calculator provides estimates of the errors associated with using isolation amplifier devices in a current sensing configuration.
Unterstützte Produkte und Hardware

Unterstützte Produkte und Hardware

Produkte
Trennverstärker
AMC1202 Isolierter Basisverstärker mit ±50-mV-Eingang und präziser Strommessung AMC1300 &Plusmn;250-mV-Eingang, Präzisions-Strommessverstärker mit verstärkter Isolierung AMC1300B-Q1 Präzisions-Verstärker für die Automobilindustrie, ±250 mV-Eingang, verstärkt isoliert AMC1301 Präziser Verstärker mit verstärkter Isolierung, ±250 mV-Eingangsspannung zur Strommessung AMC1301-Q1 250-mV-isolierter Präzisionsverstärker mit ±Eingängen und 3µs Verzögerung für die Automobilindustrie AMC1302 &Plusmn;50-mV-Eingang, Präzisions-Strommessverstärker mit verstärkter Isolierung AMC1302-Q1 Präzisions-Verstärker für die Automobilindustrie, ±50 mV-Eingang, verstärkt isoliert AMC1311 Verstärker mit verstärkter Isolierung, mit präziser Spannungsmessung, 2 V Eingangsspannung AMC1311-Q1 Verstärker mit verstärkter Isolierung für die Automobilindustrie mit 2-V-Eingang für die Spannung AMC1350 &Plusmn;5-V-Eingang, Präzisions-Spannungsmessung verstärkter isolierter Verstärker AMC1351 0-V- bis 5-V-Eingang, Präzisions-Spannungsmessung Verstärker mit verstärkter Isolierung AMC1400 &Plusmn;250-mV-Eingang, Präzisions-Strommessverstärker mit verstärkter Isolierung mit hohem CMTI< AMC1400-Q1 Reinforced-Trennverstärker für die Automobilindustrie, ±250-mV Eingangsspannung, mit hohem CMTI zur AMC1411 Verstärker mit verstärkter Isolierung, mit präziser Spannungsmessung und hohem CMTI, 2 V Eingangs AMC1411-Q1 Reinforced-Trennverstärker für die Automobilindustrie, 2 V Eingangsspannung, mit hohem CMTI zur präz AMC3301 Isolierter, verstärkter Präzisionsverstärker mit einem Eingang von ±250 mV mit integriertem DC/DC-Wa AMC3301-Q1 Verstärker mit ±250 mV-Eingang, verstärkt isoliert, mit int. für die präzise Strommessung in der Aut AMC3302 Isolierter, verstärkter Präzisionsverstärker mit einem Eingang von ±50 mV mit integriertem DC/DC-Wan AMC3302-Q1 Verstärker mit ±50 mV-Eingang, verstärkt isoliert, mit int. für die präzise Strommessung in der Auto AMC3330 Isolierter, verstärkter Verstärker mit einem Eingang von ±1 V mit integriertem DC/DC-Wandler für die AMC3330-Q1 Reinforced-Trennverstärker für die Automobilindustrie, ±1-V Eingang, mit int. zur präzisen Spannungs ISO224 &Plusmn;12-V-Eingang, Präzisions-Spannungsmessung verstärkter isolierter Verstärker
Simulationstool

PSPICE-FOR-TI — PSpice® für TI Design-und Simulationstool

PSpice® für TI ist eine Design- und Simulationsumgebung, welche Sie dabei unterstützt, die Funktionalität analoger Schaltungen zu evaluieren. Diese voll ausgestattete Design- und Simulationssuite verwendet eine analoge Analyse-Engine von Cadence®. PSpice für TI ist kostenlos erhältlich und (...)

Viele TI-Referenzdesigns beinhalten AMC1311

Mit unserem Referenzdesign-Auswahltool können Sie die für Ihre Anwendung und Ihre Parameter am besten geeigneten Designs durchsehen und ermitteln.

Gehäuse Pins CAD-Symbole, Footprints und 3D-Modelle
SOIC (DWV) 8 Ultra Librarian

Bestellen & Qualität

Beinhaltete Information:
  • RoHS
  • REACH
  • Bausteinkennzeichnung
  • Blei-Finish/Ball-Material
  • MSL-Rating / Spitzenrückfluss
  • MTBF-/FIT-Schätzungen
  • Materialinhalt
  • Qualifikationszusammenfassung
  • Kontinuierliches Zuverlässigkeitsmonitoring
Beinhaltete Information:
  • Werksstandort
  • Montagestandort

Empfohlene Produkte können Parameter, Evaluierungsmodule oder Referenzdesigns zu diesem TI-Produkt beinhalten.

Support und Schulungen

TI E2E™-Foren mit technischem Support von TI-Ingenieuren

Inhalte werden ohne Gewähr von TI und der Community bereitgestellt. Sie stellen keine Spezifikationen von TI dar. Siehe Nutzungsbedingungen.

Bei Fragen zu den Themen Qualität, Gehäuse oder Bestellung von TI-Produkten siehe TI-Support. ​​​​​​​​​​​​​​

Videos