AFE4510

ACTIVO

Circuito frontal analógico (AFE) integrado ultrapequeño para análisis de bioimpedancia y detección b

Detalles del producto

Applications 1-lead ECG, Dry electrode ECG, Impedance spectroscopy, Optical-HRM Number of input channels 4 Resolution (Bits) 22 Number of LEDs 8 Interface type SPI Operating temperature range (°C) -40 to 85 Rating Catalog
Applications 1-lead ECG, Dry electrode ECG, Impedance spectroscopy, Optical-HRM Number of input channels 4 Resolution (Bits) 22 Number of LEDs 8 Interface type SPI Operating temperature range (°C) -40 to 85 Rating Catalog
DSBGA (YBG) 42 7.606386 mm² 2.997 x 2.538
  • Integrated signal chains for Bio-Z, EDA, ECG, PPG
  • Synchronized ECG, PPG enables PTT-based BP
  • Bio-Z signal acquisition:
    • Multi-frequency Body impedance Analysis with frequency programmable up to 250kHz
    • Low frequency excitation mode for EDA/GSR
    • Complex (I, Q). Tetrapolar impedance measurement
    • Sine-wave excitation with a 7-bit DAC
    • Calibration scheme to compensate for electrode impedance and achieve accurate BioZ
  • ECG signal acquisition:
    • 1-lead ECG signal acquisition up to 4kHz
    • Mode to configure as 2-channel ECG
    • INA gain programmable from 1.27 - 12.23
    • RLD output to set body bias through the third electrode
    • Input noise (0.5-150Hz): 0.5µVrms at gain of 12.23
    • >1GΩ input impedance, CMRR>100dB
    • Integrated 370 Hz anti-aliasing low pass filter
    • AC, DC lead-off detect: 1.6nA to 1µA
  • PPG signal acquisition:
    • Acquisition of 24 PPG signal sets (LED, AMB)
    • Supports PPG sensors at different data rates
    • Peak system SNR of 115 dB in 0.5-10Hz band enables high-accuracy SpO2 measurement
    • Low Current for Continuous Operation with a Typical Value: 19µA for the Receiver
  • PPG Transmitter:
    • 8-Bit Programmable LED Current with a range adjustable from 50mA to 300mA
    • LED Short Detection
    • Support of 16 LEDs in Common Anode configuration for SpO2, OHRM, Spectroscopy
  • PPG Receiver:
    • Supports 5 PDs, 4 parallel receive paths
    • Noise filtering with programmable bandwidth
    • Trans-impedance Gain: 3.7kΩ to 1MΩ
    • 8-bit Ambient Offset Subtraction DAC up to 256µA
    • 9-bit LED Offset Subtraction DAC up to 64µA
    • Digital Ambient Subtraction at ADC Output
  • EDA Signal Acquisition:
    • Low-power continuous EDA and PPG acquisition using the ECG receiver
    • Independent data rates for EDA and PPG acquisition with optimized power cycling
    • High-accuracy EDA signal chain for spot-check EDA using the BIA signal chain
  • Supports external clock and internal oscillator
  • Option to operate 2 AFEs in parallel
  • Option to configure the 5th PD input as a general purpose voltage measurement channel
  • FIFO with 384-sample Depth, SPI™
  • Supplies: RX,:1.7-1.9V, I/O: 1.15-1.9V, TX:3-5.5V
  • Integrated signal chains for Bio-Z, EDA, ECG, PPG
  • Synchronized ECG, PPG enables PTT-based BP
  • Bio-Z signal acquisition:
    • Multi-frequency Body impedance Analysis with frequency programmable up to 250kHz
    • Low frequency excitation mode for EDA/GSR
    • Complex (I, Q). Tetrapolar impedance measurement
    • Sine-wave excitation with a 7-bit DAC
    • Calibration scheme to compensate for electrode impedance and achieve accurate BioZ
  • ECG signal acquisition:
    • 1-lead ECG signal acquisition up to 4kHz
    • Mode to configure as 2-channel ECG
    • INA gain programmable from 1.27 - 12.23
    • RLD output to set body bias through the third electrode
    • Input noise (0.5-150Hz): 0.5µVrms at gain of 12.23
    • >1GΩ input impedance, CMRR>100dB
    • Integrated 370 Hz anti-aliasing low pass filter
    • AC, DC lead-off detect: 1.6nA to 1µA
  • PPG signal acquisition:
    • Acquisition of 24 PPG signal sets (LED, AMB)
    • Supports PPG sensors at different data rates
    • Peak system SNR of 115 dB in 0.5-10Hz band enables high-accuracy SpO2 measurement
    • Low Current for Continuous Operation with a Typical Value: 19µA for the Receiver
  • PPG Transmitter:
    • 8-Bit Programmable LED Current with a range adjustable from 50mA to 300mA
    • LED Short Detection
    • Support of 16 LEDs in Common Anode configuration for SpO2, OHRM, Spectroscopy
  • PPG Receiver:
    • Supports 5 PDs, 4 parallel receive paths
    • Noise filtering with programmable bandwidth
    • Trans-impedance Gain: 3.7kΩ to 1MΩ
    • 8-bit Ambient Offset Subtraction DAC up to 256µA
    • 9-bit LED Offset Subtraction DAC up to 64µA
    • Digital Ambient Subtraction at ADC Output
  • EDA Signal Acquisition:
    • Low-power continuous EDA and PPG acquisition using the ECG receiver
    • Independent data rates for EDA and PPG acquisition with optimized power cycling
    • High-accuracy EDA signal chain for spot-check EDA using the BIA signal chain
  • Supports external clock and internal oscillator
  • Option to operate 2 AFEs in parallel
  • Option to configure the 5th PD input as a general purpose voltage measurement channel
  • FIFO with 384-sample Depth, SPI™
  • Supplies: RX,:1.7-1.9V, I/O: 1.15-1.9V, TX:3-5.5V

The AFE4510 is a versatile signal acquisition system that supports acquiring PPG, EDA, ECG, and Bio-impedance signals. A PPG signal chain comprises a current driver for LEDs and a receiver that senses the signal from PDs. An ECG receiver with a Right-leg drive (RLD) can acquire a single-lead ECG from a pair of electrodes. An impedance measurement signal chain with integrated excitation & sense can be used for applications like BIA, EDA, and Impedance spectroscopy. The outputs of the various signal chains are digitized by a common ADC and stored in a FIFO which can be read out using an SPI interface

The AFE4510 is a versatile signal acquisition system that supports acquiring PPG, EDA, ECG, and Bio-impedance signals. A PPG signal chain comprises a current driver for LEDs and a receiver that senses the signal from PDs. An ECG receiver with a Right-leg drive (RLD) can acquire a single-lead ECG from a pair of electrodes. An impedance measurement signal chain with integrated excitation & sense can be used for applications like BIA, EDA, and Impedance spectroscopy. The outputs of the various signal chains are digitized by a common ADC and stored in a FIFO which can be read out using an SPI interface

Descargar Ver vídeo con transcripción Video
Request more Information

Full data sheet and other design resources are available under NDA. Request now

Documentación técnica

star =Principal documentación para este producto seleccionada por TI
No se encontraron resultados. Borre su búsqueda y vuelva a intentarlo.
Ver todo 1
Tipo Título Fecha
* Data sheet AFE4510 Ultra Small, Integrated AFE for Bio Impedance Analysis, Electrical Bio Sensing & Optical Bio Sensing datasheet PDF | HTML 21 mar 2024

Diseño y desarrollo

Para conocer los términos adicionales o los recursos necesarios, haga clic en cualquier título de abajo para ver la página de detalles cuando esté disponible.

Placa de evaluación

AFE4510EVM — Módulo de evaluación AFE4510

El AFE4510 admite la obtención de señales sincronizadas para fotopletismograma (PPG), electrocardiograma (ECG) y análisis de impedancia corporal (BIA). La salida del convertidor analógico a digital (ADC) de las tres cadenas de señal se almacena en un bloque con configuración primero en entrar, (...)

Herramienta de simulación

PSPICE-FOR-TI — PSpice® para herramienta de diseño y simulación de TI

PSpice® for TI is a design and simulation environment that helps evaluate functionality of analog circuits. This full-featured, design and simulation suite uses an analog analysis engine from Cadence®. Available at no cost, PSpice for TI includes one of the largest model libraries in the (...)
Encapsulado Pines Símbolos CAD, huellas y modelos 3D
DSBGA (YBG) 42 Ultra Librarian

Pedidos y calidad

Información incluida:
  • RoHS
  • REACH
  • Marcado del dispositivo
  • Acabado de plomo/material de la bola
  • Clasificación de nivel de sensibilidad a la humedad (MSL) / reflujo máximo
  • Estimaciones de tiempo medio entre fallas (MTBF)/fallas en el tiempo (FIT)
  • Contenido del material
  • Resumen de calificaciones
  • Monitoreo continuo de confiabilidad
Información incluida:
  • Lugar de fabricación
  • Lugar de ensamblaje

Los productos recomendados pueden tener parámetros, módulos de evaluación o diseños de referencia relacionados con este producto de TI.

Soporte y capacitación

Foros de TI E2E™ con asistencia técnica de los ingenieros de TI

El contenido lo proporcionan “tal como está” TI y los colaboradores de la comunidad y no constituye especificaciones de TI. Consulte los términos de uso.

Si tiene preguntas sobre la calidad, el paquete o el pedido de productos de TI, consulte el soporte de TI. ​​​​​​​​​​​​​​

Videos