ISO1050
- Meets the requirements of ISO11898-2
- 5000-V RMS isolation (ISO1050DW)
- 2500-V RMS isolation (ISO1050DUB)
- Fail-safe outputs
- Low loop delay: 150 ns (typical), 210 ns (maximum)
- 50-kV/µs typical transient immunity
- Bus-fault protection of –27 V to 40 V
- Driver (TXD) dominant time-out function
- I/O voltage range supports 3.3 V and 5 V microprocessors
- Safety-related certifications
- VDE approval per DIN EN IEC 60747-17 (VDE 0884-17)
- UL 1577 approved
-
CSA approved for IEC 61010-1, IEC 60601-1
- TUV Reinforced Insulation Approval for EN/UL/CSA 62368-1 (ISO1050DW-Only)
- CQC reinforced insulation per GB4943.1 (ISO1050DW-only)
- Typical 25-year life at rated working voltage (see application report SLLA197 and Life Expectancy vs Working Voltage)
The ISO1050 is a galvanically isolated CAN transceiver that meets the specifications of the ISO11898-2 standard. The device has the logic input and output buffers separated by a silicon oxide (SiO 2) insulation barrier that provides galvanic isolation of up to 5000 V RMS for ISO1050DW and 2500 V RMS for ISO1050DUB. Used in conjunction with isolated power supplies, the device prevents noise currents on a data bus or other circuits from entering the local ground and interfering with or damaging sensitive circuitry.
As a CAN transceiver, the device provides differential transmit capability to the bus and differential receive capability to a CAN controller at signaling rates up to 1 megabit per second (Mbps). The device is designed for operation in especially harsh environments, and it features cross-wire, overvoltage and loss of ground protection from –27 V to 40 V and overtemperature shutdown, as well as –12V to 12V common-mode range.
The ISO1050 is characterized for operation over the ambient temperature range of –55°C to 105°C.
관심 가지실만한 유사 제품
다른 핀 출력을 지원하지만 비교 대상 장치와 동일한 기능
기술 자료
설계 및 개발
추가 조건 또는 필수 리소스는 사용 가능한 경우 아래 제목을 클릭하여 세부 정보 페이지를 확인하세요.
ISO1050EVM — ISO1050 절연 CAN 트랜시버 평가 모듈
This multi-functional evaluation module (EVM) is designed for the evaluation of the ISO1050 isolated CAN transceiver. Input and output connections, as well as test points for measurements, are provided to help you use this device which is the world's first CAN transceiver with integrated isolation.
TMDXIDDK379D — 산업용 모터 제어용 C2000 DesignDRIVE 개발 키트
The DesignDRIVE Development Kit (IDDK) hardware offers an integrated servo drive design with full power stage to drive a high voltage three-phase motor and eases the evaluation of a range of position feedback, current sensing and control topologies.
The sensing peripherals on the C2000™ MCU, (...)많은 TI 레퍼런스 설계에는 ISO1050이(가) 포함됩니다.
레퍼런스 디자인 선택 툴을 사용하여 애플리케이션 및 매개 변수에 가장 적합한 설계를 검토하고 식별할 수 있습니다.
패키지 | 핀 | CAD 기호, 풋프린트 및 3D 모델 |
---|---|---|
SOIC (DW) | 16 | Ultra Librarian |
SOP (DUB) | 8 | Ultra Librarian |
주문 및 품질
- RoHS
- REACH
- 디바이스 마킹
- 납 마감/볼 재질
- MSL 등급/피크 리플로우
- MTBF/FIT 예측
- 물질 성분
- 인증 요약
- 지속적인 신뢰성 모니터링
- 팹 위치
- 조립 위치
권장 제품에는 본 TI 제품과 관련된 매개 변수, 평가 모듈 또는 레퍼런스 디자인이 있을 수 있습니다.