TPS40130
Controlador CC/CC reductor multifásico de 2 canales con controladores integrados
Hoja de datos
TPS40130
- Two-Phase Interleaved Operation
- 3-V to 40-V Power Stage Operation Range
- Supports Up to 6-V VOUT With External Divider
- Requires VIN5 @ 50 mA, Typical, Depending on External MOSFETs and Switching Frequency
- 1-µA Shutdown Current
- Programmable Switching Frequency up to 1 MHz/Phase
- Current Mode Control with Forced Current Sharing
- Better than 1% Internal 0.7-V Reference
- Resistive Divider Sets Direct Output Over Voltage Threshold and Sets Input Undervoltage Lockout
- True Remote Sensing Differential Amplifier
- Resistive or Inductor’s DCR Current Sensing
- 30-pin TSSOP or 32-Pin QFN Packages
- Can Be Used with TPS40120 to Provide a 6-Bit Digitally Controlled Output
- APPLICATIONS
- Graphic Cards
- Internet Servers
- Networking Equipment
- Telecommunications Equipment
- DC Power Distributed Systems
The TPS40130 is a two-phase synchronous buck controller that is optimized for low-output voltage, high-output current applications powered from a supply between 3 V and 40 V. A multi-phase con- verter offers several advantages over a single power stage including lower current ripple on the input and output capacitors, faster transient response to load steps, improved power handling capabilities, and higher system efficiency.
Each phase can be operated at a switching frequency up to 1 MHz, resulting in an effective ripple frequency of up to 2 MHz at the input and the output. The two phases operates 180 degrees out-of-phase.
Documentación técnica
No se encontraron resultados. Borre su búsqueda y vuelva a intentarlo.
Ver todo 2 Tipo | Título | Fecha | ||
---|---|---|---|---|
* | Errata | TPS40130 Enable Reference Voltage Interaction Errata | 17 jun 2006 | |
* | Data sheet | 2- PHASE CONTROLLER datasheet (Rev. B) | 27 jul 2005 |
Pedidos y calidad
Información incluida:
- RoHS
- REACH
- Marcado del dispositivo
- Acabado de plomo/material de la bola
- Clasificación de nivel de sensibilidad a la humedad (MSL) / reflujo máximo
- Estimaciones de tiempo medio entre fallas (MTBF)/fallas en el tiempo (FIT)
- Contenido del material
- Resumen de calificaciones
- Monitoreo continuo de confiabilidad
Información incluida:
- Lugar de fabricación
- Lugar de ensamblaje