Startseite Energiemanagement DC/DC-Spannungsversorgungsmodul Isolierte Stromversorgungsmodule (integrierter Transformator)
NEU

UCC33410

VORSCHAU

Isoliertes 5 V bis 3,3 V, 1W 3kV rms-DC/DC-Modul mit integriertem Transformator

Produktdetails

Features 1W, Basic isolation, Regulated, Single output Output power (W) 1 Vin (min) (V) 4.5 Vin (max) (V) 5.5 Vout (max) (V) 3.4 Device type Isolated modules Isolation rating Basic Regulated outputs (#) 1 Rating Catalog Operating temperature range (°C) -40 to 125 TI functional safety category Functional Safety-Capable Vout (min) (V) 3.2
Features 1W, Basic isolation, Regulated, Single output Output power (W) 1 Vin (min) (V) 4.5 Vin (max) (V) 5.5 Vout (max) (V) 3.4 Device type Isolated modules Isolation rating Basic Regulated outputs (#) 1 Rating Catalog Operating temperature range (°C) -40 to 125 TI functional safety category Functional Safety-Capable Vout (min) (V) 3.2
— (—) See data sheet
  • 1.0W Maximum output power
  • 4.5V to 5.5V input voltage operation range
  • 3.3V, 3.7V regulated selectable output voltage
    • 3.3V: 300mA available load current
  • 0.5% typical load regulation
  • 2mV/V typical line regulation
  • Robust isolation barrier:
    • Isolation rating: 3kVRMS
    • Surge capability: 6.5kVPK
    • Working voltage: 1159VPK
    • 200V/ns common mode transient immunity
  • Power dense isolated DC/DC module with integrated transformer technology
  • Adaptive spread spectrum modulation (SSM)
  • Meets CISPR32 Class B emission
  • Strong magnetic fields immunity
  • Overload and short circuit protection
  • Thermal shutdown
  • Low inrush current soft-start
  • Enable pin with fault reporting mechanism
  • Planned Safety-related certifications:
    • Basic isolation per DIN EN IEC 60747-17 (VDE 0884-17)
    • 3kVRMS isolation for 1 minute per UL 1577
    • UL certification per IEC 62368-1, and IEC 60601-1 end equipment standards
    • CQC approval per GB4943.1-2022
  • Extended temperature range: –40°C to 125°C
  • VSON-12 (4.0mm × 5.00mm) package
  • 1.0W Maximum output power
  • 4.5V to 5.5V input voltage operation range
  • 3.3V, 3.7V regulated selectable output voltage
    • 3.3V: 300mA available load current
  • 0.5% typical load regulation
  • 2mV/V typical line regulation
  • Robust isolation barrier:
    • Isolation rating: 3kVRMS
    • Surge capability: 6.5kVPK
    • Working voltage: 1159VPK
    • 200V/ns common mode transient immunity
  • Power dense isolated DC/DC module with integrated transformer technology
  • Adaptive spread spectrum modulation (SSM)
  • Meets CISPR32 Class B emission
  • Strong magnetic fields immunity
  • Overload and short circuit protection
  • Thermal shutdown
  • Low inrush current soft-start
  • Enable pin with fault reporting mechanism
  • Planned Safety-related certifications:
    • Basic isolation per DIN EN IEC 60747-17 (VDE 0884-17)
    • 3kVRMS isolation for 1 minute per UL 1577
    • UL certification per IEC 62368-1, and IEC 60601-1 end equipment standards
    • CQC approval per GB4943.1-2022
  • Extended temperature range: –40°C to 125°C
  • VSON-12 (4.0mm × 5.00mm) package

UCC33410 is an industrial DC/DC power module with integrated transformer technology designed to provide 1.0W of isolated output power. It can support an input voltage operation range of 4.5V to 5.5V and regulate 3.3V output voltage with a selectable headroom of 3.7V.

UCC33410 features a proprietary transformer architecture that achieves a 3kVRMS isolation rating, while simultaneously supporting low EMI and excellent load regulation.

The UCC33410 integrates protection features for increased system robustness such as enable pin with fault reporting mechanism, short circuit protection and thermal shutdown.

The UCC33410 comes in a miniaturized, low-profile solution VSON (4.0mm × 5.00mm) package with 1.00mm height and > 4.1mm creepage and clearance

UCC33410 is an industrial DC/DC power module with integrated transformer technology designed to provide 1.0W of isolated output power. It can support an input voltage operation range of 4.5V to 5.5V and regulate 3.3V output voltage with a selectable headroom of 3.7V.

UCC33410 features a proprietary transformer architecture that achieves a 3kVRMS isolation rating, while simultaneously supporting low EMI and excellent load regulation.

The UCC33410 integrates protection features for increased system robustness such as enable pin with fault reporting mechanism, short circuit protection and thermal shutdown.

The UCC33410 comes in a miniaturized, low-profile solution VSON (4.0mm × 5.00mm) package with 1.00mm height and > 4.1mm creepage and clearance

Herunterladen Video mit Transkript ansehen Video
Weitere Informationen anfordern

Das vollständige Datenblatt und weitere Designressourcen stehen zur Verfügung. Jetzt anfordern

Technische Dokumentation

star =Von TI ausgewählte Top-Empfehlungen für dieses Produkt
Keine Ergebnisse gefunden. Bitte geben Sie einen anderen Begriff ein und versuchen Sie es erneut.
Alle anzeigen 2
Typ Titel Datum
* Data sheet UCC33410 Ultra-Small, 1.0W , 3.3V , 3kVRMS Isolation, Industrial DC/DC Module datasheet PDF | HTML 19 Jun 2024
Certificate UCC33420EVM-080 EU Declaration of Conformity (DoC) 19 Jan 2024

Design und Entwicklung

Weitere Bedingungen oder erforderliche Ressourcen enthält gegebenenfalls die Detailseite, die Sie durch Klicken auf einen der unten stehenden Titel erreichen.

Evaluierungsplatine

UCC33420EVM-080 — UCC33420 evaluation module

The UCC33420EVM-080 is intended to allow designers to evaluate the performance and capabilities of the UCC33420. UCC33420 is an isolated DC/DC converter module able to deliver 1.5W with 3kVrms of isolation in a very small and compact VSON-12 (4 mm by 5 mm by 1 mm) package, reducing footprint and (...)

Benutzerhandbuch: PDF | HTML
Gehäuse Pins CAD-Symbole, Footprints und 3D-Modelle
— (—)

Bestellen & Qualität

Beinhaltete Information:
  • RoHS
  • REACH
  • Bausteinkennzeichnung
  • Blei-Finish/Ball-Material
  • MSL-Rating / Spitzenrückfluss
  • MTBF-/FIT-Schätzungen
  • Materialinhalt
  • Qualifikationszusammenfassung
  • Kontinuierliches Zuverlässigkeitsmonitoring
Beinhaltete Information:
  • Werksstandort
  • Montagestandort

Support und Schulungen

TI E2E™-Foren mit technischem Support von TI-Ingenieuren

Inhalte werden ohne Gewähr von TI und der Community bereitgestellt. Sie stellen keine Spezifikationen von TI dar. Siehe Nutzungsbedingungen.

Bei Fragen zu den Themen Qualität, Gehäuse oder Bestellung von TI-Produkten siehe TI-Support. ​​​​​​​​​​​​​​

Videos